39
EKI-136x-MB-BE Series User Manual
4.4
Network Settings
4.4.1
LAN
To access this page, click
Network Settings
>
LAN
.
Figure 4.3 Network Settings > LAN
The following table describes the items in the previous figure.
Local Network
Local IP Address
Displays the assigned IP address of the device.
Local Netmask
Displays the assigned netmask of the device.
MAC Address
Displays the MAC address of the device.
Item
Description
Item
Description
Local Hostname
Enter the device name: up to 31 alphanumeric characters.
Network mode
Click the drop-down menu to select the IP Address Setting mode:
Static, DHCP/AutoIP, BOOTP/AutoIP or DHCP/BOOTP/AutoIP.
IP Address
Enter a value to specify the IP address of the interface. The default
is 10.0.0.1.
Subnet Mask
Enter a value to specify the IP subnet mask for the interface. The
default is 255.255.255.0.
Default Gateway
Enter a value to specify the default gateway for the interface.
DNS
Click the radio button to select the DNS mode: Automatic or
Specific.
DNS 1
Enter a value to specify the default DNS 1 for the interface.
DNS 2
Enter a value to specify the default DNS 2 for the interface.
DHCP Timeout
Enter a value to specify the timeout for getting response from
DHCP server, the device will give up the request and take next
action.
MAC Address
Display the MAC address to which packets are statically
forwarded.
Apply
Click
Apply
to save the values and update the screen.
Summary of Contents for EKI-136-MB-BE Series
Page 1: ...User Manual EKI 136x MB BE Series 1 2 port RS 232 422 485 to 802 11a b g n WLAN Modbus Gateway...
Page 11: ...Chapter 1 1Introduction...
Page 16: ...Chapter 2 2Getting Started...
Page 32: ...Chapter 3 3Utility Configuration...
Page 46: ...Chapter 4 4Web Interface...
Page 71: ...Chapter 5 5Telnet Serial Console Configuration...