2 ECU-P1706 Startup Manual
PIN Assignment
I/O Connector Signal Description
Signal
Name
Reference Direction Description
AI<0..7>+
AGND
Input
Analog positive input
channels 0 through 7.
AI<0..7>-
AGND
Input
Analog negative input
channels 0 through 7.
AIGND,
AOGND
-
Analog GND
AO0_VOUT
AO1_VOUT
AGND
Input
Analog voltage output
channels 0/1
AO0_IOUT
AO1_IOUT
AGND
Input
Analog current output
channels 0/1
DIO<0:15> DGND
Inout
Digital inout channels,
direction can be set by
software
DGND
-
Digital GND
CNT0_CLK
CNT1_CLK
IGND
Input
Counter clock external
Input. External (1 Hz
to 1 MHz) or internal
(20MHz), set by
software
CNT0_OUT
CNT1_OUT
IGND
Output
Counter out
CNT0_
GATE
CNT1_
GATE
IGND
Input
Counter gate
EXT_
SCAN_CLK
DGND
Input
Scan clock external
Input. External (up to
250 K) or internal (up
to 10 M)
EXT_
CONV_CLK
DGND
Input
Convert clock external
Input. External (up to
250 K) or internal(up
to 10 M)
EXT_AI_Tri DGND
Input
AI Trigger external
Input. External, Analog,
software, as set by
software
Specifications
General
Power Consumption:
Typical: 5V @ 850mA
Bus Type:
PCI-104
I/O Connector:
Plug-in Terminal Block
Operating Temperature:
-20 ~ 70°C (-4 ~
158°F) @ 5 ~ 85% RH
Storage Temperature:
-40 ~ 80°C (-40 ~176°F)
Storage Humidity:
5 ~ 95% RH, non-
condensing (IEC 60068-2-3)
Analog Input
Channels:
8 differential
Resolution:
16 bits
Sampling Rate:
250 KS/s
FIFO Size:
8 K samples
Overvoltage:
30 VP-P Protection
Input Impedance:
18 Mohm
Sampling Mode:
Software, onboard
programmable pacer and external (TTL Level)
Trigger Mode:
Delay to Start trigger, Delay to
Stop trigger
Trigger Source:
Analog Trigger, External
Trigger
Input Range:
(V. Software Programmable)
Bipolar
±10
±5
±2.5
±1.25
Accuracy % of
FSR±1LSB
0.04
0.04
0.06
0.08
Timer Counter
Channels:
2
Resolution:
2 bits
Mode In:
Event counting, Frequency/PWM In
Compatibility:
Isolated 24 V
DC
Max. Input Frequency:
1 MHz
Max. Output Frequency:
1 MHz