APPENDIX B: PRODUCT SPECIFICATIONS
GENERAL SPECIFICATIONS
Hardware &
Included
Accessories
Device
Serial Server
CD
CD with Vlinx Manager Software for: Windows 2000, XP (32/64 bit),
2003 Server (32/64 bit), Vista (32/64 bit), 2008 Server (32/64 bit),
2012 Server-r2 (32/64 bit), 7 (32/64 bit), 8 (32/64 bit), 10 (32/64 bit)
Optional
Accessories
Cable
Model# 232NM9 - Null Modem Crossover Cable, for DTE to DTE
connection
DIN Rail
For DIN rail mounting (35 mm)
Extra Mounting Bracket Kit
Model# 9030
Configuration
Options
Via Serial Port
Using Vlinx Manager via a serial connection, (press Reset button to
enter Console Mode)
Via Network
Using Vlinx Manager via a Ethernet connection.
Using a standard web browser, such as Internet Explorer 7, 8 or 9 or
Firefox 3 or 4.
Software
Vlinx Manager for Serial
Server Configuration
Windows 2000, XP (32/64 bit), 2003 Server (32/64 bit), Vista (32/64
bit), 2008 Server (32/64 bit), 2012 Server-r2 (32/64 bit), 7 (32/64 bit), 8
(32/64 bit), 10 (32/64 bit)
Environment
Operating Temperature
-40 to +80 °C (-40 to +176 °F)
Storage Temperature
-40 to +85 °C (-40 to +185 °F)
Operating Humidity
10 to 95%, non-condensing
Maximum Ambient
Surrounding Air
Temperature
+80 °C
Certifications
FCC
Part 15 Class A
UL
Class 1, Div. 2, Groups A, B, C, D
NEMA TS2
CE - Directives
2014/30/EU – Electromagnetic Compatibility
2011/65/EU – Reduction of Hazardous Substances (RoHS)
2012/19/EU – Waste Electrical and Electronic Equipment (WEEE)
CE - Standards
EN 55032 Class B – Electromagnetic compatibility of multimedia
equipment – Emission requirements
EN 55024 – Information Technology Equipment – Immunity
characteristics – Limits and methods of measurement
EN 61000-6-1 – Generic immunity standards for residential,
commercial and light-industrial environments
EN 61000-6-2 – Generic standards - Immunity (heavy) industrial
environments
Enclosure
Rating
IP30
Mounting
DIN rail mount (35 mm)
Dimensions
4.57 x 12.2 x 17.1 cm (1.8 x 4.4 x 6.75 in)
Power Supply
Voltage Requirements
10 to 48 VDC (58 VDC, maximum)
Power Consumption
6.0 Watts, maximum
Source
External (power supply required, not included, sold separately)
Locking Barrel
Connector Input
Voltage Requirements: 10 to 30 VDC, maximum.
Class 2, Grounded Type Supply Only.
NOTE: Coaxial power cable must be in accordance with Class 2 requirements in Article 725 of NEC.
The locking barrel connector must NOT be used in a hazardous environment.
Terminal
Blocks
Wire Size
28 to 16 AWG
Wire Type
Copper Wire Only
Tightening Torque
5 KG-CM
Wire Temperature
Rating
105 °C, minimum
Sized for 60 °C Ampacity
NOTE:
One Conductor Per Terminal