IE-iMcV-T1-Mux/4+Ethernet
14
CONFIGURATION OPTIONS
The following sections describe the configurable features.
From the CLI "Unit Configuration," use the "Factory Default" command to
restore the unit's default settings in the CLI, under Unit Configuration. This
restores the card's default configuration and resets the default username and
password.
User:
admin
/ Password:
admin
ETHERNET PORT
If the Ethernet port is not used, it can be set to disabled via a console session
or via iView², to effectively block all traffic on this port.
PACKET SIZE
The Ethernet port can accommodate packets up to 1916 bytes.
AUTO NEGOTIATION
The IE-iMcV-T1-Mux/4 + Ethernet ships from the factory with Auto Negotiation
enabled on the Ethernet port. In this mode, the port negotiates for speed,
duplex and flow control.
FORCING SPEED, DUPLEX MODE, FLOW CONTROL
The Ethernet port on the IE-iMcV-T1-Mux/4 + Ethernet can be selectively
advertised or manually forced for 10 Mbps or 100 Mbps operation at Half- or
Full-Duplex (i.e., 10 Mbps Full-Duplex, 10 Mbps Half-Duplex, 100 Mbps Full-
Duplex, etc.). Flow control can also be enabled on the Ethernet port when the
connecting equipment supports this. These features can be enabled through
iView²/CLI.
BANDW IDTH CONTROL
The IE-iMcV-T1-Mux/4 + Ethernet includes bi-directional bandwidth control in
32 Kbps increments (configurable via iView2).
FX LINKLOSS AND LFPT
During normal operation, link integrity pulses are transmitted by all point-to-
point Ethernet devices. When an IE-iMcV-T1-Mux/4 + Ethernet receives valid
link pulses, it knows that the device to which it is connected is up/acyive, and