IE-iMcV-T1-Mux/4+Ethernet
13
INSTALLATION INSTRUCTIONS
Each IE-iMcV-T1-Mux/4 + Ethernet module requires two slots in an iMedia
Chassis series, MediaChassis/2 series, or IE-MediaChassis/2 series. To install
the module in a chassis:
1. Remove the blank faceplates covering the slots where the module is
to be installed.
2. Then slide the module into the chassis card guides until the module
is seated securely in the slots.
3. Secure the module to the chassis by tightening the captive screw.
All IE-iMcV-T1-Mux/4 + Ethernet units are shipped from the factory configured
as
Host
units. The IE-iMcV-T1-Mux/4 + Ethernet modules must be installed in
pairs. For two IE-iMcV-T1-Mux/4 + Ethernet units to properly operate together
one unit needs to be configured as a
Remote
. Configuration as a Host or
Remote is controlled via a DIP Switch setting (S1-1).
NOTE
:
Some options require items that are sold separately, available from B+B SmartWorx.
SMALL FORM-FACTOR PLUGGABLE PORTS (SFP)
The fiber link on the IE-iMcV-T1-Mux/4 + Ethernet module is supported
through one or two SFPs (depending on model) running at 155Mbps. Many
SFPs, including those from B+B SmartWorx, feature enhanced diagnostics
capabilities Data and Diagnostic Management Information (DDMI). DDMI
statistics provide real-time access to transceiver operating parameters such as
voltage, temperature, laser bias current, and both transmitted and received
optical power. DDMI information can be accessed in iView
2
. Any MSA-
compliant SFP, 155mbps, can be installed in one or both SFP ports (model
specific).
AUTOCROSS FEATURE
The 10/100BaseT Ethernet port on the IE-iMcV-T1-Mux/4 + Ethernet includes
an AutoCross feature that automatically selects between a crossover
workstation and a straight-through connection depending on the connected
device.