Appendix A Voltage Specifications
53
Overshoot (resistive load):
Any output overshoot when the power is turned on does not
exceed 10% of the nominal output voltage.
Output power:
Maximum continuous: 310 W
Power good and power fail signals (optional)
:
When the power is turned on, the power good signal will acti-
vate 100 to 500 ms after all output DC voltages are operating
within their respective regulation limits. The power fail signal
will activate at least 1 ms before the +5 V output voltage falls
below its regulation limit.
Short circuit protection:
A short circuit placed on any output to ground is shut down.
When the short circuit conditions have ceased to exist, power
will then be recycled to restart the power supply.
Over-current protection:
The power supply will shut down all the DC outputs when any
output is overloaded beyond its current limit or beyond its
nominal line voltage limit. When the over-current conditions
have ceased to exist, power will then be recycled to restart the
power supply.
Current limit ranges: 5 V: 32 ~ 45 A
12 V: 13 ~ 20 A
-12 V: 6 ~ 12 A
-5 V: 1.5 ~ 3 A
Over-voltage protection:
The power supply will shut down all the DC outputs when any
output maximum voltage limit is exceeded. When the over-
voltage conditions have ceased to exist, power will then be
recycled to restart the power supply.
Summary of Contents for AWS-8430T
Page 1: ...AWS 8430T Industrial Workstation with 12 1 Flat Panel Display...
Page 12: ...xii...
Page 22: ...10 AWS 8430T User s Manual...
Page 26: ...14 AWS 8430T User s Manual Figure 2 2 Removing the rear door...
Page 30: ...18 AWS 8430T User s Manual Figure 2 6 Hold down clamp...
Page 32: ...20 AWS 8430T User s Manual 8...
Page 33: ...Chapter 2 System Setup 21 9...
Page 34: ...22 AWS 8430T User s Manual Figure 2 10 Installing a primary HDD...
Page 40: ...28 AWS 8430T User s Manual...
Page 48: ...36 AWS 8430T User s Manual...
Page 54: ...42 AWS 8430T User s Manual...
Page 80: ...68 AWS 8430T User s Manual 5 Press OK...
Page 84: ...72 AWS 8430T User s Manual...