68
AWS-825B/PB User’s Manual
Line regulation:
The output line regulation for each output is less than ±1%, when
measured at each output’s respective rated load and under ±10%
changing input voltage conditions.
Load regulation:
The values for each of the following output numbers were obtained
by changing each output load ±40% from the 60% rated load,
whilst simultaneously keeping all other outputs at 60% of their
respective rated loads.
Table B-6: 24 V
DC
power supply load regulation
Output No.
Load regulation
1
±4%
2
±5%
3
±3%
4
±3%
Power good signal:
When the power is turned on, the power good signal will activate
100 to 500 ms after all output DC voltages are operating within
their respective regulation limits.
Power fail signal:
This will activate at least 0.5 ms before any of the output voltages
fall below their respective regulation limits.
Summary of Contents for AWS-825B
Page 1: ...AWS 825B PB Industrial Workstation with 15 Color CRT Display ...
Page 10: ...x ...
Page 11: ...Introduction Description Specifications Front and rear panel layout Dimensions CHAPTER 1 ...
Page 20: ...10 AWS 825B PB User s Manual ...
Page 23: ...Chapter 2 System Setup 13 Figure 2 1 Detaching the work drawer ...
Page 30: ...20 AWS 825B PB User s Manual ...
Page 35: ...Chapter 3 Maintenance 25 Figure 3 4 Removing the CRT monitor final steps ...
Page 37: ...Chapter 3 Maintenance 27 Figure 3 6 Keyboard translator input output schematic ...
Page 42: ...32 AWS 825B PB User s Manual Figure 3 10 Replacing the membrane keypad ...
Page 44: ...34 AWS 825B PB User s Manual Figure 3 11 Replacing the touchscreen sensor ...
Page 52: ...42 AWS 825B PB User s Manual ...
Page 62: ...52 AWS 825B PB User s Manual ...
Page 63: ...15 Monitor Specifications APPENDIX A ...
Page 66: ...56 AWS 825B PB User s Manual ...
Page 80: ...70 AWS 825B PB User s Manual ...
Page 88: ...78 AWS 825B PB User s Manual a Add M6 behind monmouse in autoexec bat to add drag 15 END ...
Page 94: ...84 AWS 825B PB User s Manual a 9 Test the calibration END ...