ARMA-K100-CRM
29
12. ‘1’ - A request to go LOCAL was issued / ‘0’- no event
13. ‘1’ - Computer interface in control / ‘0’- Hardware interface in control (if byte #9 is a ‘1’)
F3 –
Messag
: request for alarm or fault message. No message bytes are shown if no message is
available. See ‘F2’ response byte 11.
F4 –
Param
: request for various parameters. After disregarding the header 00A, the ASCII
character ‘P’ (for parameters) is followed by a list of monitored parameters:
‘
A
’ is followed by the set attenuation level (in dB)
‘
C
’ is followed by supply current (in A)
‘
M
’ is followed by the user-set alarm threshold for the output power (in dBm)
‘
O
’ is followed by the output power level (in dBm)
‘
R
’ is followed by the reflected power level (in dBm)
‘
TM
’ is followed by the power module hot spot temperature (in
°
Celsius)
‘
TS
’ is followed by the shroud temperature (in
°
Celsius)
‘
VS
’ is followed by the supply voltage (in VDC)
F5 -
Reset
: resets faults and restarts the unit for all alarm conditions except over temperature
(which restarts by itself when the unit cools down).
F6 –
MUTEon
: command to MUTE the unit (no RF output power).
F7 –
Muteof
: command that brings the amplifier back to its RF ON state.
F8 –
Atten
: Sets the attenuation level. For 0 dB attenuation, enter 0; for 15 dB attenuation, enter
150; for 18 dB attenuation, enter 180 (0.1 dB steps, no decimal point required).
F9 –
Unit#
: selects the unit with which the PC is communicating. Any value between 0 and 15
(default value: 0)
F10 –
More
: to go to next menu (screen) page.