2.2

Signal Connection and Pin Assignment

2.2.1

Isolated Digital Input and Trigger

The AIIS-1882 has 4 trigger inputs and 12 digital inputs. The digital input and trigger

accepts only wet contact.

 

Figure 2.5 Isolated digital input and trigger connection

2.2.2

Isolated Digital Output

The digital outputs of AIIS-1882 are designed sink type and source type switchable

via software. See the below connection diagram.
- Sink type (NPN)

 

Figure 2.6 Sink type isolated digital output connection

Summary of Contents for AIIS-1882

Page 1: ...User Manual AIIS 1882 4 Channel PWM Lighting Controller Module for AIIS Vision System ...

Page 2: ... assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced free of charge during the warranty period For out of warranty repairs customers will be billed according to the cost ...

Page 3: ...quipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful interference In such cases users are required to correct the interference at ...

Page 4: ...lack 1 x 4 pin terminal blocks green 4 x Lighting cable 4 x Screws for module assembly 4 x Screw posts for module assembly 1 x I O panel 3 x Screws for front panel 1 x PCB supporting pad Warning Warnings indicate conditions that if not observed can cause personal injury Caution Cautions are included to help prevent hardware damage and data losses For example Batteries are at risk of exploding if i...

Page 5: ...ur liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If any of the following occurs have the equipment checked by service person nel The power cord or plug is damaged Liquid has penetrated the equipment The equipment has been exposed to moisture The equipment is malfunc...

Page 6: ...s könnte einen Brand bzw elektrischen Schlag aus lösen 13 Öffnen Sie niemals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden 14 Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen Netzkabel oder Netzstecker sind beschädigt Flüssigkeit ist in das Ge...

Page 7: ...To avoid electrical shock always disconnect the power from the PC chassis before manual handling Do not touch any components on the CPU card or other cards while the PC is powered on Disconnect the power before making any configuration changes A sudden rush of power after connecting a jumper or installing a card may damage sensitive electronic components ...

Page 8: ...AIIS 1882 User Manual viii ...

Page 9: ... Output 10 Figure 2 8 Lighting output connection 10 2 2 4 Pin Assignment 11 Figure 2 9 Layout view of AIIS 1882 11 Figure 2 10Front view of AIIS 1882 11 Figure 2 11Pin assignment of digital I O and trigger 11 Figure 2 12Pin assignment of external power 12 Figure 2 13Pin assignment of 2 pin lighting connector 12 Figure 2 14Pin assignment of 3 pin lighting connector 12 Chapter 3 Function Details 13 ...

Page 10: ...d Lighting output with trigger edge setting High 20 Figure 3 15Gated Lighting output with trigger edge setting Low 20 3 5 Device Description and Configuration 21 Figure 3 16Device description shown in Navigator 21 3 6 Device Test in Navigator Utility 22 Figure 3 17Profile setting of AIIS 1882 22 Figure 3 18Device Test for digital input 22 Figure 3 19Device Test for digital output 23 Figure 3 20Dev...

Page 11: ...Chapter 1 1 Start Using AIIS 1882 ...

Page 12: ...PWM high low time and output lighting duration Up to 350 mA and 40 VDC digital output capability by external power 12 ch isolated digital input and 16 ch isolated digital output Software configurable digital filter for isolated digital input and trigger Software selectable sink NPN source PNP type for isolated digital output 2 500 VDC isolation protection for all I O signals 1 2 Driver Installatio...

Page 13: ...see AIIS 1882 in the Installed Devices list 1 4 Software Development Using DAQNavi SDK DAQNavi SDK is the software development kit for programming applications with Advantech DAQ products The necessary runtime DLL header files software man ual and tutorial videos could be installed via XNavi installer They can be found under C Advantech DAQNavi default directory after finishing the installation 1 ...

Page 14: ...AIIS 1882 User Manual 4 ...

Page 15: ...Chapter 2 2 Installation and Field Application ...

Page 16: ...p enclosure of AIIS 3411 3 Remove 4 screws around the expansion connectors 4 Remove the screws of the I O panel 5 Remove I O panel Figure 2 1 Disassembling the enclosure of AIIS 3411 Then assemble the AIIS 1882 board in the chassis lighting cables to the front panel finally the I O panel back to the front panel 1 Screw the four screw posts back into the holes that they came from 2 Remove the relea...

Page 17: ...he board for CN10 13 figure 2 3 6 Plug the other end of the lighting cables into the front panel CN10 to LT0 CN11 to LT1 CN12 to LT2 CN13 to LT3 figure 2 3 7 Screw the I O panel back onto the front panel 8 Screw the top enclosure back onto the AIIS 3411 Figure 2 2 Assemble the AIIS 1882 into AIIS 3411 ...

Page 18: ...AIIS 1882 User Manual 8 Figure 2 3 Lighting cable assembly Figure 2 4 Module support pad sticking ...

Page 19: ...igger inputs and 12 digital inputs The digital input and trigger accepts only wet contact Figure 2 5 Isolated digital input and trigger connection 2 2 2 Isolated Digital Output The digital outputs of AIIS 1882 are designed sink type and source type switchable via software See the below connection diagram Sink type NPN Figure 2 6 Sink type isolated digital output connection ...

Page 20: ...lated digital output connection 2 2 3 Lighting Output The lighting output provides internal 12V at maximum 1A capacity for each channel Connecting external power could increase the capacity to 2A to each channel and also 24V option Figure 2 8 Lighting output connection ...

Page 21: ... digital output CN5 DC IN External power for lighting output 1 4 CN14 LT n Lighting output n n 1 4 connected via 3 pin cable to be assembled on the front panel CN10 CN13 Pin name Description Pin Number DICOM Common pin for isolated digital input 1 2 IDI n Isolated digital input n n 0 11 3 14 Trigger n Trigger input for lighting n n 0 3 15 18 NC Reserved 19 20 DOCOM Common pin for isolated digital ...

Page 22: ...ighting connector 3 pin Lighting Connectors LT0 LT3 This is the optional lighting connection for AIIS 1882 Pin define as below Figure 2 14 Pin assignment of 3 pin lighting connector Pin Name Description Pin Number Power V Positive pin for external power input 2 3 Power V Negative pin for external power input 1 4 Pin Name Description Pin Number Lighting V PWR_OUT Positive pin for lighting 2 Lightin...

Page 23: ...Chapter 3 3 Function Details ...

Page 24: ...unctions 3 1 1 1 Digital Input Interrupt All digital input channels can generate software interrupts or events to notice the application about the state change of input signals Interrupts can occur at rising edge falling edge or both edges of the digital input signal as shown in Figure 3 3 Figure 3 4 and Figure 3 5 respectively The enable disable interrupt function and the selection of interrupt e...

Page 25: ...3 Digital Input Debounce Filter To prevent false interrupts due to noise or bouncing in the signal the digital input sig nals can be filtered If digital input filter is enabled transient signals with duration smaller than the filter duration will be considered as glitches and will not generate interrupts as shown in Figure 3 7 Digital input debounce filter can be enabled or dis abled independently...

Page 26: ...pdate 3 3 PWM Lighting Output Control The lighting control leverages a PWM Pulse Width Modulation mechanism A pulse waveform with specified high period tHIGH and low period tLOW is output at counter output terminal as shown in Figure 3 6 Figure 3 8 Pulse width modulation output The lighting intensity is controlled by PWM high period For example in the same PWM cycle period 100ms setting 100ms as h...

Page 27: ...iod 3 Strobe single PWM output The corresponded parameters to configure are high period low period and output count The high period and low period define the PWM high and low time span in a period of PWM output respectively The output count specifies the number of PWM period that the output generates in each output cycle The configuration interface in Navigator is as shown below Figure 3 10 PWM pr...

Page 28: ...te lighting output it s suggested to set the frequency of output much larger 10 100x than the camera frame rate so that the PWM output could evenly distributed within the camera exposure period For example the maximum frame rate of the camera is 500fps it means the exposure period is 2ms so for the PWM period we suggest at least 0 2ms As a result the high and low periods should be set within 0 2ms...

Page 29: ...me rate isn t one of the constrains The low period could be any number or kept to the shortest it can be because the only thing that affects the application is the high period The table below lists some examples for different settings and results Low could be set to any figure as long as it wouldn t affect the cycle time Camera Frame Rate fps Frame Period ms PWM Period ms Intensity High ms Low ms ...

Page 30: ...e High and Low The trigger delay can also be set in order to generate a specific lighting with delayed period D Note that with Trig ger Edge configured High or Low the Trigger Delay and Output Count is invalid Fig ure 3 10 to 3 13 describes the lighting reactions under each trigger edge setting Figure 3 12 Finite pulse generation with delay and rising edge Figure 3 13 Finite pulse generation with ...

Page 31: ...ifferentiate the modules in the system It s given by combining the model name and boardID 0 for AIIS 1882 You can change the description in Navigator or just leave it as default The description is used in your own program in order to get control or device handler from the device Figure 3 16 Device description shown in Navigator ...

Page 32: ... All of these function tests can be found in Device Test in Navigator The parameter set in the Profile page will be applied to Device Test as long as the profile is saved Figure 3 17 Profile setting of AIIS 1882 Digital Input Switch the tab to Digital Input then connect the signal to digital input pin The indica tors on the panel will turn red or green according to the input status Figure 3 18 Dev...

Page 33: ... e g LED to digital output pin Press the button then the output will react accordingly Figure 3 19 Device Test for digital output PWM Lighting Output Switch the tab to Counter then connect the lighting directly to LT1 4 Set the PWM high low period Check the Start box will start the lighting output Figure 3 20 Device Test for lighting output ...

Page 34: ...AIIS 1882 User Manual 24 ...

Page 35: ...Appendix A A Specifications ...

Page 36: ...ponse This is measured without external loading Channels 4 Input voltage Logic 0 2 V max Logic 1 5 V min 24 V max wet contact only Digital Filter 16μs 131 ms Isolation protection 2 500 VDC Response time 15 μs max Channels 12 Input voltage referenced to DICOM terminal Logic 0 3 V max Logic 1 10 V min 40 V max Type unipolar Input protection voltage 70 V Input resistance 3 kΩ typ Isolation protection...

Page 37: ...l Current limit protection Yes Flyback diode protection Yes Isolation protection 2 500 VDC ON state resistance 0 2 Ω max Response time 100 μs max Update type Instant I O Connector 2x 20 pin connector for DIO and trigger 4x 2 pin header for PWM lighting control power 1 GND 1 1x 4 pin connector for external power input Dimensions L x W 175 x 101 mm 6 89 x 3 98 Operating Temperature 0 60 C 32 140 F S...

Page 38: ...re subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permission from the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2022 ...

Reviews: