3.4.2 Operation Mode Configuration
COM Redirector Setting:
The Advantech serial device servers extend traditional COM ports of a
PC to Ethernet access. Through Ethernet networking, users can control
and monitor remote serial devices and equipments over LAN or WAN.
Advantech serial device servers come with a COM port redirector
(Virtual COM driver) that transmits all serial signals intact. This means
that your existing COM-based software can be preserved, without modi-
fying to fulfill the needs. The Virtual COM mode allows user to continue
using RS-232 serial communications software that was written for pure
serial communication applications.
The ADAM-4570 series comes with COM port redirector (virtual COM
driver) that work with series comes with COM port redirector Window
2000/XP/Vista systems. The driver establishes a transparent connection
between host and serial device by mapping the IP of Advantech serial
device server serial port to a local COM port on the host computer.
The ADAM-4570 series provides Multi-access function through Ethernet
connection path. Allow the maximum of 5 connections to open one serial
port simultaneously. In this mode, all connection has to use the same
serial setting. If one serial setting of these connections is different from
others, the data communication may operate incorrectly.
Summary of Contents for ADAM-4570
Page 9: ...2 CHAPTER 1 Overview ...
Page 14: ...ADAM 4570 Series User Manual 6 ...
Page 15: ...2 CHAPTER 2 Getting Started ...
Page 25: ...17 Chapter2 RJ 48 DB 9 PIN Name DCD RX TX DTR GND DSR RTS CTS RI RJ 48 1 2 3 4 5 6 7 8 9 ...
Page 29: ...2 CHAPTER 3 Configuration ...
Page 59: ...2 CHAPTER 4 Setting the COM Redirector ...
Page 68: ...ADAM 4570 Series User Manual 60 ...
Page 69: ...2 APPENDIX A Pin Assignments ...
Page 71: ...2 APPENDIX B Creating VCOM ...
Page 74: ...ADAM 4570 Series User Manual 66 Now you have two mapped VCOM in your host ...