6. MAINTENANCE
This Section describes the scheduled maintenance procedure for the SSPB.
CAUTION!
Improper maintenance of the SSPB may void the warranty.
6.1 PREVENTIVE MAINTENANCE
This product requires minimum maintenance, which consists of visual inspection and cleaning.
WARNING! Personnel
performing
maintenance
on this system must have the proper
training and become thoroughly familiar with the related safety requirements and issues.
Read and practice the safety guidelines as described in (Section 1 at page 6).
6.1.1 M
ECHANICAL
P
REVENTIVE
M
AINTENANCE
Mechanical preventive maintenance consists of verifying the condition of all mechanical parts
with the AC power switched off. Perform the following inspection:
1. With the AC power disconnected or switched off, check that all of the connectors and plugs
are seated properly in their mating-connectors and have not been damaged. Replace any
damaged connector plugs and reset any that are dislodged.
Inspect the electrical wiring for signs of discolored, broken or poor insulation. Repair or replace
as required.
Check for other defects such as breakage, fungus, deterioration, excess moisture and mounting
integrity.
6.1.2 C
HECKING THE
C
OOLING
F
ANS
The cooling fans are located at the input connectors side of the shroud of the SSPB. Verify that
the fans are operating smoothly. Any suspect noise may indicate wear and the respective fan will
have to be replaced. Check for debris or dust in the fans intake and in all openings on the unit.
Any obstruction may reduce the efficiency of the cooling system. The fans should be replaced
every two years, in order to ensure the proper cooling of the unit.
WARNING:
Do not come in contact with any electrical assembly while power is applied.
Page
24
Summary of Contents for SSPBMg-C400-BRE
Page 12: ...SSPBMg C400 BRE Figure 1 Product Outline Page 11 ...
Page 13: ...SSPBMg C400 BRE Figure 2 Product Outline fans side view Page 12 ...
Page 17: ...SSPBMg C400 BRE Figure 4 Connectors Page 16 ...
Page 29: ...SSPBMg C400 BRE Figure 7 HyperTerminal RS 232 Communication help command and response Page 28 ...