• open any valves at the inlet and outlet of the booster pump before operation

• set all filtration system valves in a manner that does not deprive the booster pump of water during

operation

• do not operate the booster pump without a pressure cleaner connected to the system

• set time clocks such that the booster pump only operates when the filtration system is on

• clean filtration system regularly to prevent flow restrictions

CAUTION –

RISK OF EQUIpmENT DAmAGE.

Do NOT add chemicals to pool/spa

system directly in front of pump suction. Adding undiluted chemicals may damage pump and voids
warranty.

If filtration system pump is to be turned off for any reason, then the booster pump must be turned off
before turning off the filtration system pump.

NOTE –

If the Advantage booster pump is used to replace the booster pump in an existing pressure

cleaner  installation,  then  the  cleaner  operating  pressure  should  be  reset  according  to  the  cleaner
manufacturer’s recommended procedure.

mAINTENANCE

• Advantage pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.

• Keep motor clean. Insure motor air vents are free from obstruction to avoid damage. Do NOT use

water to hose off motor.

• Occasionally,  shaft  seals  must  be  replaced,  due  to  wear  or  damage.  See  “Shaft  Seal  Change

Instructions” in this manual.

Storage/Winterization

WARNING –

Separation hazard.

Do not purge the system with compressed

air. Purging the system with compressed air can cause components to explode, with risk
of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high
volume blower when air purging the pump, filter, or piping.

ATTENTION –

Allowing the pump to freeze will void the warranty.

ATTENTION –

Use ONLY propylene glycol as antifreeze in your pool/spa system. Propylene

glycol is nontoxic and will not damage plastic system components; other anti-freezes are highly toxic
and may damage plastic components in the system.

Drain all water from pump and piping when expecting freezing temperatures or when storing pump
for a long time (see instructions below). Gravity drain system as far as possible.

Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do NOT cover
or wrap pump with plastic film or bags. 

10

INSTALLATION INSTRUCTIONS

Summary of Contents for PC34

Page 1: ...s manual carefully and completely CAUTION We highly recommend a qualified professional install and service this product WARNING This manual contains important safety information that must be furnished to the end user of this product FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY SAVE THIS INSTRUCTION MANUAL PC34 OWNER S MANUAL INSTALLATION OPERATION PARTS ...

Page 2: ...ode NEC ATTENTION INSTALLER ThIS mANUAL CONTAINS ImpORTANT INFORmATION ABOUT ThE INSTALLATION OpERATION AND SAFE USE OF ThIS pUmp ThAT mUST BE FURNIShED TO ThE END USER OFThIS pRODUCT FAILURE TO READAND FOLLOWALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY WARNING To reduce risk of injury do not permit children to use or climb on this product Closely supervise children at all times Components such...

Page 3: ...onductor size 8 or larger Run a continuous wire from external bonding lug to reinforcing rod or mesh Connect a No 8 AWG 8 4 mm2 solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5m of inside walls of swimming pool spa o...

Page 4: ... all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while system pump is running Before starting system pump fully open filter manual air relief valve Do not close filter manual air relief valve until a steady stream of water not air or air and water mix is discharged from the valve All suction and discharge valv...

Page 5: ...ump is exceptionally quiet and uses up to 40 less electricity than competitive booster pumps Pump design allows for easy installation and service Suitable for use with all pressure cleaners requiring a booster pump Tall mounting base allows for increased motor ventilation as well as protection from flooding Drain plug requires no tools for installation and removal Volute may be re oriented in the ...

Page 6: ...clean Pump motors require free circulation of air for cooling pUmp mOUNTING Install pump on a level concrete slab or other rigid base to meet all local and national codes Secure pump to base with screws or bolts to further reduce vibration and stress on pipe or hose joints The base must be level rigid and vibration free pump mount must Allow pump inlet height to be as close to water level as possi...

Page 7: ...strict flow For better efficiency use the fewest possible fittings but at least two suction outlets Avoid fittings that could cause an air trap Pool and spa fittings MUST conform to the InternationalAssociation of Plumbing and Mechanical Officials IAPMO standards Use a non entrapping suction fitting in pool multiple drains or double suction skimmer and main drain pipe Sizing Chart 7 INSTALLATION I...

Page 8: ...ing on electrical connections Fire hazard match supply voltage to motor nameplate voltage Insure that the electrical supply available agrees with the motor s voltage phase and cycle and that the wire size is adequate for the HP kW rating and distance from the power source Use copper conductors only Voltage Voltage at motor mUST NOT be more than 10 above or below motor name plate rated voltage or m...

Page 9: ...l suction and discharge valves mUST be OpEN as well as filter manual air relief valve if available on filter when starting the circulating pump system for the first time or after servicing the system Failure to do so could result in severe personal injury Starting the pump The filtration system pump must be running and an automatic pool cleaner must be connected before starting the booster pump If...

Page 10: ...bearings and shaft seals No lubrication is necessary Keep motor clean Insure motor air vents are free from obstruction to avoid damage Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage See Shaft Seal Change Instructions in this manual Storage Winterization WARNING Separation hazard Do not purge the system with compressed air Purging the system with ...

Page 11: ...fety precautions should always be observed including the following Failure to follow instructions may result in severe personal injury or death A WARNING To reduce risk of injury do not permit children to use this product B Disconnect all electrical power service to pump before beginning shaft seal replacement C Only qualified personnel should attempt rotary seal replacement Contact your local aut...

Page 12: ...3 of this manual for pump component locations 7 Clean and lightly lubricate the motor shaft and seal recesses in the seal plate item 7 with a dilute solution of nongranulated liquid type soap Gently wipe the polished face of the ceramic seal with a soft cotton cloth Lubricate the rubber cup on the ceramic seat and press it firmly into the recess of the seal plate item 7 with the polished ceramic s...

Page 13: ...ller 6 310108 Shaft Seal Assembly 7 310109 Seal Plate Assembly 8 310110 Nut 9 310111 Shaft Adapter 10 310112 Base Mounting Bolts 11 310113 Motor Support Base 12 310114 Motor Base Insulator 13 310115 Motor Insulator Ref No part No Description PARTS LIST FOR PC34 PUMP 3 4 5 6 1 2 7 9 10 11 8 12 13 ...

Page 14: ...e the debris Low Flow Generally Check For 1 Clogged or restricted strainer or suction line Solution Contact a qualified repair professional 2 Undersized pool piping Solution Correct piping size 3 Plugged or restricted discharge line of filter valve partially closed high gauge reading Solution Sand filters backwash as per manufacturer s instructions D E filters backwash as per manufacturer s instru...

Page 15: ...uct Incidental consequential or other damages will not be paid by Advantage Inc including but not limited to the cost of labor and or water or chemical loss or any damages that occur Damage cause by improper chemical treatment or corrosion Damage caused by Acts of God or nature Employment of the product for other than it s intended use Motor damage caused by improper electrical connections and or ...