4
II. Unpacking
The MicroTron™ pump has been shipped as a complete package, ready for installation.
If the shipping carton shows any signs of damage, notify the shipping company immediately
upon receipt. Advantage Controls cannot be held responsible for damage from shipping.
Unpack the carton and insure the following items are present:
1.
Metering pump
4.
Injection fitting
2.
Suction, discharge and priming tubing
5.
Instruction manual
3.
Foot valve and weight
III. Safety Considerations
NOTE: All MicroTron™ pumps are primed with water before leaving the factory. If the
solution to be pumped is not compatible with water, disassemble the pump fluid end before
use. After disassembly, thoroughly dry the pump head, valves, and seals before pump is
reassembled and used.
A. Chemical Compatibility
MicroTron™ metering pumps are designed to work with most liquid chemicals depending upon
your pump’s liquid end materials of construction. A chemical resistance chart is available for
determining specific compatibility with a wide variety of chemicals. If you have further
compatibility questions, contact Advantage Controls service department at 1-800-743-7431.
B. Safety and Preparation
Always wear the proper protective clothing and gear when working around chemicals and
chemical metering pumps. Safety glasses, gloves, and aprons are critical in preventing accidental
exposure to dangerous chemicals. Liquids under pressure can present a special hazard when
a line or seal is punctured resulting in the spraying of chemical many yards away. If a chemical
spillage occurs, consult the Material Safety Data Sheet (MSDS) for specific instructions regarding
the chemical being used.
IV. Installation
A. Location
Select a mounting location convenient to the chemical supply as well as a source of power
for the pump. Do not install the pump in a location where the ambient temperature exceeds
120 degrees F (50
o
C). Higher temperatures will affect the output as well as the useful life of
the pump. While the MicroTron™ pump is suitable for most outdoor installations, do not use
the standard poly tubing in direct sunlight. If you must mount pump in direct sunlight or under
bright fluorescent lights use ultra-violet resistant tubing, consult your distributor or the factory.
Accessory item R00225 (plastic mounting bracket) is recommend for a secure installation.