Excessive fluid
Failure or lack of antisiphon valve
Excessive stroke rate
Improper stroke length
Inspect or add anti-siphon valve. This is
caused when system is in a vacuum condition
or valve in delivery applications with flooded
suction which feeds systems at very low
pressures.
Lower the stroke rate if adjustable on your
pump.
Reduce stroke length.
Pump will not pump
System pressure too high
Diaphragm improperly installed
Check valves worn or clogged
Check system pressure to assure that it
is within system rated paramaters of the
pressure.
Make sure that diaphragm is screwed fully
unto shaft.
Clean or replace as required.
Pump will not run not
plugged in
Pump not turned on or not plugged in
Electronic failure
Check outlet with meter to assure that correct
or voltage is present and that power supply
cord is in good condition and plugged in.
Consult dealer or factory.
Excessive noise
Pump not primed
No output pressure
Prime pump.
Add an anti-siphon valve to provide 25 PSI
restriction on pump discharge.
X. Manufacturer’s Product Warranty
Advantage Controls warrants units of its manufacture to be free of defects in material or
workmanship. Liability under this policy extends for 24 months from date of installation. Liability is limited
to repair or replacement of any failed equipment or part proven defective in material or workmanship upon
manufacturer’s examination. Removal and installation costs are not included under this warranty.
Manufacturer’s liability shall never exceed the selling price of equipment or part in question.
Advantage disclaims all liability for damage caused by its products by improper installation,
maintenance, use or attempts to operate products beyond their intended functionality, intentionally or
otherwise, or any unauthorized repair. Advantage is not responsible for damages, injuries or expense
incurred through the use of its products.
The above warranty is in lieu of other warranties, either expressed or implied. No agent of ours is
authorized to provide any warranty other than the above.
30 Day Billing Memo Policy
Advantage Controls maintains a unique factory exchange program to ensure uninterrupted service
with minimum downtime. If your unit malfunctions, call 1-800-743-7431, and provide our technician with
Model and Serial Number information. If we are unable to diagnose and solve your problem over the phone,
a fully warranted replacement unit will be shipped, usually within 48 hours, on a 30-Day Billing Memo.
This service requires a purchase order and the replacement unit is billed to your regular account for
payment. The replacement unit will be billed at current list price for that model less any applicable resale
discount. Upon return of your old unit, credit will be issued to your account if the unit is in warranty. If the unit
is out of warranty or the damage not covered, a partial credit will be applied based upon a prorated
replacement price schedule dependent on the age of the unit. Any exchange covers only the controller
or pump. Electrodes, liquid end components and other external accessories are not included.