Installation and Operation Manual S400 series
16
2.4.9. Resetting data in the memory
At any time, the memory of the Multi display can be returned to factory settings. To do so, a
memory reset command is accessible in the menu. The following parameters are restored in the
memory:
Speed unit:
Knots
Depth unit:
Metres
Distance unit:
Nautical Miles
Temperature unit:
°Celsius
Speed damping:
10 seconds
Speed calibration coeff.:
Slope at 1.0
Temp. calibration coeff.:
Offset to 0
Keel offset:
0
Depth alarms:
deactivated, high and low threshold at 0
Speed alarms:
deactivated, high and low threshold at 0
Temperature alarms:
deactivated, high and low threshold at 0
Battery alarm:
deactivated, low threshold at 0
Countdown timer init.:
10 minutes
Trip log:
0
Total log:
0
Simulation mode:
deactivated
Backlighting level:
0 (OFF)
Press
menu
for 2 seconds, then
menu
until the "rESEt" page is
displayed, then activate (on) or deactivate (OFF) the reset using
the
and
keys.
Press
to exit setup mode, or time out after 10 seconds.
2.5. Standby
To save energy on board, the "MULTI" display can be placed on standby by pressing for 5
seconds on the
key.
Standby mode switches off backlighting, the screen, stops sensor measurement and processing
of NMEA input and output interfaces. Only the vital bus management and keyboard functions
remain active. Active displays present on the bus indicate measurement impossible with an OFF
icon instead of the data.
Standby mode is not saved.
At any time, simply pressing one of the four keys or cutting
off the power stops standby mode and returns all device functions to normal.