Page 13 of 16
TROUBLESHOOTING
Fan System:
The fan system consists of two primary elements: Fan Blade and Motor
Problem
Check
Solution
Fan won’t run and makes no sound.
Power cord, extension cord, switches, and circuit
breaker.
Reconnect power or extension cord.
Reset breaker.
Fan motor won’t run and makes a
humming sound.
Motor stalled (will not turn by hand).
Replace motor.
Breaker trips or fuse blows when fan is
started.
Motor stall.
Check power source for min. 115v/10 amp.
Extension cord adequacy.
Replace motor.
Upgrade power supply.
Replace with heavier cord.
Motor overheating and shutting off.
Restarting several minutes later.
Extension cord gauge too small.
Inlet air obstructed or too close to wall.
Faulty motor.
Replace with heavier cord.
Provide additional inlet clearance.
Replace motor.
Fan motor won’t run and switch makes
soft clicking sound.
Switch making good contact.
Replace switch.
Water Systems:
The water delivery system consists of four primary elements: Water Hose, Float Assembly, Pump,
and Water Distribution Channel
.
Problem
Check
Solution
Floor at side of the unit is wet.
Water inlet hose is loose at supply
hose.
Tighten connections and/or replace
hose washers.
The unit overflows from reservoir.
Float valve hose is loose at bulkhead
fitting or at float valve.
Water pressure is too high to allow
float valve to shutoff (60psi max).
Float valve is not seating properly.
Tighten connections and/or replace
hose washers.
Reduce water pressure by adding an
inline pressure reducer.
Check float valve.
Replace float
Water leaking from drain valve.
Make sure drain nut is secure.
Tighten drain nut.
Too many dry streaks in the pads.
Holes in water distribution tray are
blocked.
Remove distribution tray and clean
Water spitting from the unit.
Hose connection loose.
Tighten hose.
Replace hose and washer.
Pump motor will not run when switch
is turned on.
Check switch, cord and circuit
breakers.
Replace switch and reset breaker.
ELECTRICAL SHOCK HAZARD
•
Serious injury or death may
occur.
•
Disconnect from electrical
supply before servicing this
product.