Advanced Energy
®
COOLING REQUIREMENTS
Ensure that exhausted air does not circulate back into the unit and become input air
.
Also, ensure that all cooling requirements are within specification. See
"Cooling
Specifications" on page 3-14
.
Tools Required for I nstallation
AE supplies the following equipment:
• Two AC
MAINS
cables. Use the cable appropriate to your location.
• If the
PLASMA/LOAD
connector on your V arioMatch match network is MC6 or
6 mm brass tube fittings, AE supplies the matching plug. See the
"Physical
Specifications" on page 3-1
to see which
PLASMA/LOAD
connector your unit
uses.
For successful installation, you will need to supply the following additional
equipment:
• Four M6 mounting screws (preferab
l
y brass) and an appropriate screwdriver.
• If the
PLASMA/LOAD
connector on your V arioMatch match network is a strap
connection, you need to supply the strap connector and the ground strap. See the
"Physical Specifications" on page 3-1
to see which
PLASMA/LOAD
connector
your unit uses.
•
For water-coo
l
ed units: Plastic hose 6 mm O
D
/ 4 mm ID (0.24" OD/ 0.16" ID)
(see
"Connecting the Cooling Water" on page 5-7
).
•
Cab
l
es (see also
"Connector/Cable specifications" on page 3-3
):
► Shielded 50
n
coaxial cable for RF input from the generator
►
RF cabling to connect the unit to a generator. See
"Cable Requirements" on
page 5-3
.
► Communication interface cable if you will use remote control of the
u
ni
t.
•
If you purchased an ICP unit, you must supply the tune coil. See the
"Physical
Specifications" on page 3-1
to see if your unit is ICP.
Unpacking
5-2
Unpack and inspect the unit carefully, looking for obvious physical damage. If no
damage is apparent, proceed with the installation. If you do see signs of shipping
damage, contact Advanced Energy
®
and the carrier immediate
l
y (see
"Contacting AE
Global Services" on page 6-4
). Save the shipping container for submitting necessary
claims to the carrier.
I
nstallat
i
on
,
Setup, and Operat
i
on
57020080-00D
Summary of Contents for VarioMatch Match Network VM 1000 Platform
Page 2: ......
Page 6: ...Advanced Energy vi 57020080 00D...
Page 10: ...Advanced Energy X Table of Contents 57020080 00D...
Page 12: ...Advanced Energy xii List of Tables 57020080 00D...
Page 16: ...Advanced Energy 1 xvi 57020080 00D...
Page 30: ...Advanced Energy 2 8 Product Overview and T heory 57020080 00D...
Page 48: ...Advanced Energy 3 18 Specifications 57020080 00D...
Page 56: ...Advanced Energy 4 8 Communication Interfaces and Controls 57020080 00D...
Page 96: ...Advanced Energy 5 40 Installation Setup and Operation 57020080 00D...
Page 102: ...Advanced Energy 6 6 Troubleshooting and Global Services 57020080 00D...
Page 190: ...Advanced Energy 7 88 VarioMatch Match Network Tuning Ranges 57020080 00D...