4-8
5708577-A
Advanced Energy
®
FRONT PANEL SWITCHES AND INDICATORS
Figure 4-6 identifies the switches and indicators on the front panel of the AMN PS-2A
controller. Table 4-5 defines each of the numbered switches and indicators.
Figure 4-6.
AMN PS-2A Controller Front Panel
Table 4-5.
Front Panel Controls and Indicators
Number
Control/
Indicator
Description
1
FAIL
LED
When lit, this LED indicates a loss of reference
voltage from the AMN PS-2A controller to the
matching network.
2
LOAD
-
LIMIT
(minimum) LED
When lit, this LED indicates that the load
capacitor motor has reached its minimum limit.
3
LOAD
+ LIMIT
(maximum) LED
When lit, this LED indicates that the load
capacitor motor has reached its maximum
limit.
4
LOAD
meter
This meter indicates the present position of the
load capacitor.
5
Load
AUTO
/
MAN
/
REM
switch
This mode switch places motor control in one
of three operation modes: automatic, manual,
or remote.
6
Load
-
/
+
switch
When the controller is in manual mode, this
switch adjusts the load capacitor. Putting the
switch in the “
+
” position adjusts the capacitor
in the positive direction. Putting the switch in
the “
-
” position adjusts the capacitor in the
negative direction.
1
2
3
4
5
7
6
9
8
12
11
10
13
Summary of Contents for AMN PS-2A
Page 3: ......
Page 4: ...User Manual AMN PS 2A Automatic Matching Network Power Supply Controller 5708577 A...
Page 7: ...vi 5708577 A Advanced Energy...
Page 11: ...x 5708577 A Advanced Energy...
Page 13: ...xii 5708577 A Advanced Energy...
Page 19: ...1 6 5708577 A Advanced Energy...
Page 23: ...2 4 5708577 A Advanced Energy...
Page 37: ...4 10 5708577 A Advanced Energy...
Page 39: ...5 2 5708577 A Advanced Energy DIMENSIONAL DRAWING Figure 5 1 Dimensions...
Page 43: ...5 6 5708577 A Advanced Energy...