background image

Due to continuous product development Advanced Air (U.K.) Ltd 
reserves the right to change any information without prior notice. 

Burrell Way,  

Thetford, Norfolk, 

 IP24 3QU,  England 

Tel: +44 (0) 1842 753624    

   Fax: +44 (0) 1842 762032 

Email: [email protected] 

2500 Series  

Fire Smoke Dampers 

Date 

Issue 

Spec. No. 

Page No. 

04/03/14  Rev 2  CE –FSD Sub 

PATENT APPLIED FOR 

Fire Damper Testing Details 

Test House & Test

 

Fire Test

 

Integrity

 

Classification BS EN 13501-3

 

BRE - 284807 
Efectis No: R0261a 
HEVAC 

BS EN 1366-2 

120 min 

E120 (ve i

o) s 

Efectis No:  R0169b & R0169c                                             
HEVAC 

BS EN 1366-2 

120 min 

E120 (ho i

o) s 

BRE - 284809 
BRE - 284808 
AFS - Partition Wall 

BS EN 1366-2 

120 min 

E120 (ve i

o) s 

TBC 
AFS - Blockwork Wall 

BS EN 1366-2 

120 min 

E120 (ve i

o) s 

AFS - Adjustable Frame System 

(P

ATENT

 P

ENDING

)

 

With the tighter requirements of the CPR 
and Building regulations with regard to CE 
labelling and that dampers have to be 
installed as tested Advanced Air through our 
design and development program are 
please to launch the  AFS installation 
system that simplifies damper installations 
for customers. 
 
This new system  is unique to Advanced Air 
and offers one solution for fire smoke 
damper installation in walls.  Using Firebatt 
that is the accepted standard on sites to 
finish damper installation. Our fire smoke 
dampers have been successfully tested to 
BS EN 1366-2 with the same method in 
both Blockwork and Drywalls.  
 
The added benefit of this system it is 
adjustable allowing the drop rod supports to 
be positioned to suit the site conditions 

Summary of Contents for 2500 Series

Page 1: ...ble link that prevent the damper from opening if the temperature has reached 720 C With the introduction of Construction Product Regulation on the 1st July 2013 all fire dampers are required to meet t...

Page 2: ...ght to change any information without prior notice Burrell Way Thetford Norfolk IP24 3QU England Tel 44 0 1842 753624 Fax 44 0 1842 762032 Email sales advancedair co uk 2500 Series Fire Smoke Dampers...

Page 3: ...Cambered grade 430 stainless steel Top Bottom Jambs Profiled grade 430 stainless steel riveted to damper frame Minimum Duct Size Rectangular 100mm x 100mm case size 250mm x 250mm Circular 100mm diamet...

Page 4: ...i o s TBC AFS Blockwork Wall BS EN 1366 2 120 min E120 ve i o s AFS Adjustable Frame System PATENT PENDING With the tighter requirements of the CPR and Building regulations with regard to CE labellin...

Page 5: ...ngland Tel 44 0 1842 753624 Fax 44 0 1842 762032 Email sales advancedair co uk 2500 Series Fire Smoke Dampers Date Issue Spec No Page No 04 03 14 Rev 2 CE FSD Sub PATENT APPLIED FOR 5 Sizing Informati...

Page 6: ...using 750mm wide units tests performed in a clean system at suitable pressures and are P re ssu r e D r o p s F u l l y O p e n 1 1 0 1 0 0 1 0 0 0 1 1 0 1 0 0 V e lo c it y m s Pressure drop Pa 6 1 0...

Page 7: ...s aluminium alloy rivets or nylon bolts 9 All connecting ductwork must be independently supported within 1meter of the connections 10 An Access cover should be fitted on the appropriate side of the ba...

Page 8: ...y 7 The ductwork connecting to the dampers long spigot must overlap by 40mm The ductwork connecting to the short spigot must overlap the spigot by 40mm leaving 10mm clearance for any duct expansion in...

Page 9: ...tilation plant and ancillaries but should not exceed a maximum interval in excess of twelve months The report should be completed following the Maintenance Procedure included within this document Pre...

Page 10: ...ce checks can best be ascertained by system conditions or as directed by local regulations for ventilation plant and ancillaries but should not exceed a maximum interval in excess of twelve months The...

Page 11: ...ion of Fire Dampers must be done by competent trained persons who are familiar with the type of product They should follow the following essential safety practices Wear appropriate PPE gloves footwear...

Page 12: ...ght to change any information without prior notice Burrell Way Thetford Norfolk IP24 3QU England Tel 44 0 1842 753624 Fax 44 0 1842 762032 Email sales advancedair co uk 2500 Series Fire Smoke Dampers...

Page 13: ...tch wiring for damage where applicable Check damper for cleanliness and clean where necessary Check the condition of the blades and seals rectify and report where necessary Confirm the safety closure...

Reviews:

Related manuals for 2500 Series