72
- FORM NO. 56043103 - Warrior
™
ST, Warrior
™
AXP
ELECTRICAL SYSTEM
MAIN CONTROL PROGRAMMING OPTIONS (CONTINUED)
ST models:
1
Turn the main power key switch to the off position.
2
Press and hold in the scrub on switch and recycle switch.
3
While holding both switches, turn the key switch to the on position.
4
Continue to hold both switches until the recycle indicator and regular and heavy scrub indicators turn green.
5
Release both switches. The LED display will now show the current scrub pressure setting. The scrub off indicator will turn red and the regular and heavy scrub
indicators will turn yellow.
6
Press the scrub on switch to select the new extreme scrub pressure.
7
Press the scrub off switch to save the new setting and move to the solution rate setting. The solution
fl
ow indicator will display the number of bars corresponding
to the current solution
fl
ow setting, the regular and heavy scrub indicators will turn green and the solution indicator will turn yellow.
8
Press the solution switch to select the new solution
fl
ow rate.
9
Press the scrub off switch to save the new solution
fl
ow rate setting. The scrub off indicator will turn green.
10 Turn the main power key switch to the off position. The new settings will be saved and will remain in effect until they are changed again.
Recovery Tank-Full Switch Orientation:
FACTORY DEFAULT: 0 (Normally Open Position)
The Warrior control board now has a programmable option to allow it to work with a normally-open or normally-closed recovery tank full switch.
Note: The normally-open con
fi
guration is used when the
fl
oat switch is installed such that the
fl
oat hangs down when the tank is empty, then
fl
oats up
to the horizontal position when the tank is full. (See Figure 3 in Recovery System/Maintenance of Recovery Tank Float Switches.) In the normally-
closed con
fi
guration, the
fl
oat remains horizontal when the tank is empty, then
fl
oats up when the tank is full.
All current machines use the normally-open
fl
oat switch con
fi
guration, and have the programming option available in the main controller to
allow you to change the switch orientation to either normally-open or normally-closed. Earlier machines used the normally-closed con
fi
guration
only and did not have the switch orientation programming option available. If the main controller on your machine does not have the switch
orientation programming option available (as described below), you must run the machine with the switch in the normally-closed con
fi
guration.
Note that controllers on AXP machines with software revision level “I” or later, and controllers on ST machines with software revision level “E”
or later will have the switch orientation programming option. Refer to the
Displaying the Control Unit Revision Level
subsection for instructions
on how to view the software revision level of your controller.
To change the
fl
oat switch orientation option, perform the following steps:
Turn the main power key switch to the off position.
1.
2
Press and hold the scrub system off and vacuum switches.
3
While holding both switches turn the main power key switch to the on position.
4
Continue to hold both switches until only the vacuum indicator is lit (approximately 2 seconds).
5
Release both switches. The status or LED display will now indicate “0” or “1” and the scrub off indicator will be red.
6
Pressing and releasing the vacuum switch will now select between “1” for the normally closed con
fi
guration or “0” for the normally open con
fi
guration.
7
To save the new setting, press the scrub off button. The scrub off indicator will change from red to green.
8
Turn the main power key switch to the off position. The new setting will be saved and will remain in effect until it is changed again.
revised 5/08
Summary of Contents for Warrior AXP
Page 2: ......
Page 7: ...FORM NO 56043103 Warrior ST Warrior AXP 5 TECHNICAL SPECIFICATIONS...
Page 27: ...FORM NO 56043103 Warrior ST Warrior AXP 25 FIGURE 2 SCRUB SYSTEM...
Page 29: ...FORM NO 56043103 Warrior ST Warrior AXP 27 NOTES...
Page 31: ...FORM NO 56043103 Warrior ST Warrior AXP 29 FIGURE 4 SCRUB SYSTEM...
Page 57: ...FORM NO 56043103 Warrior ST Warrior AXP 55 FIGURE 4...
Page 59: ...FORM NO 56043103 Warrior ST Warrior AXP 57 FIGURE 5 ELECTRICAL SYSTEM revised 5 08 AXP MODELS...
Page 65: ...FORM NO 56043103 Warrior ST Warrior AXP 63 FIGURE 6 ELECTRICAL SYSTEM revised 5 08 AXP Models...
Page 76: ...74 FORM NO 56043103 Warrior ST Warrior AXP THIS PAGE IS INTENTIONALLY BLANK...
Page 86: ......