FORM NO. 56043103 - Warrior
™
ST, Warrior
™
AXP -
71
ELECTRICAL SYSTEM
MAIN CONTROL PROGRAMMING OPTIONS (CONTINUED)
Heavy Scrub Setting Adjustment:
FACTORY DEFAULT: SCRUB PRESSURE =2, SOLUTION = TWO BARS(#2), CHEMICAL = 0 (IF AVAILABLE).
The heavy scrub pressure, solution rate and chemical rate can be programmed depending on its application where high solution rate is need with regular scrub
pressure or low solution rate with heavy scrub pressure. To change scrub pressure setting, solution rate setting and chemical setting, perform the following steps:
AXP™ models:
1
Turn the main power key switch to the off position.
2
Press and hold the scrub on and the chemical switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold both switches until the wand indicator and heavy scrub indicator turn green.
5
Release both switches. The display will now show disc icon with current scrub pressure setting. Scrub off indicator will turn red and heavy scrub indicator will
turn yellow.
6
Pressing scrub on switch will now select new scrub pressure. Pressing scrub off switch will save the new setting and move to solution rate setting.
7
The display will now show solution icon with gauge. Heavy scrub indicator will now turn green and solution indicator will turn yellow. Pressing solution switch
will now select new solution rate. Pressing scrub off switch will save the new setting and move to chemical setting (If available).
8
The display will now show chemical bottle with current chemical setting. Solution indicator will turn green and chemical indicator will turn green. Pressing
chemical switch will now select new chemical setting. Pressing scrub off switch will save the new setting and display key switch icon on display.
9
Turn the main power key switch to the off position. The new settings will be saved and will remain in effect until they are changed again.
ST models:
1
Turn the main power key switch to the off position.
2
Press and hold in the scrub on switch and vacuum switch.
3
While holding both switches, turn the key switch to the on position.
4
Continue to hold both switches until the heavy scrub on indicator turns green and the red battery indicator light switches on.
5
Release the scrub on switch and vacuum switch. The display will show the current heavy scrub pressure setting (1-3), the scrub off indicator will turn red and
the heavy scrub on indicator will turn yellow.
6
Press the scrub on switch to select new heavy scrub pressure.
7
Press the scrub off switch to save the scrub pressure setting. The heavy scrub on indicator will be green and the solution system indicator will be yellow.
8
Press the solution switch to select the new solution rate.
9
Press the scrub off switch to save the new solution
fl
ow setting. The scrub off indicator will turn green.
10 Turn the main power key switch to the off position. The new settings will be saved and will remain in effect until they are changed again.
Extreme Scrub Setting Adjustment:
FACTORY DEFAULT: SCRUB PRESSURE =3, SOLUTION = THREE BARS(#3), CHEMICAL = 0 (IF AVAILABLE).
The extreme scrub pressure, solution rate and chemical rate can be programmed depending on its application where high solution rate is need with extreme scrub
pressure or low solution rate with heavy scrub pressure. To change scrub pressure setting, solution rate setting and chemical setting, perform the following steps:
AXP™ models:
1
Turn the main power key switch to the off position.
2
Press and hold the scrub on and the recycle switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold both switches until the recycle indicator and regular and heavy scrub indicators turn green.
5
Release both switches. The display will now show disc icon with current scrub pressure setting. Scrub off indicator will turn red and regular and heavy scrub
indicator will turn yellow.
6
Pressing scrub on switch will now select new scrub pressure. Pressing scrub off switch will save the new setting and move to solution rate setting.
7
The display will now show solution icon with gauge. Regular and heavy scrub indicators will now turn green and solution indicator will turn yellow. Pressing
solution switch will now select new solution rate. Pressing scrub off switch will save the new setting and move to chemical setting (If available).
8
The display will now show chemical bottle with current chemical setting. Solution indicator will turn green and chemical indicator will turn green. Pressing
chemical switch will now select new chemical setting. Pressing scrub off switch will save the new setting and display key switch icon on display.
9
Turn the main power key switch to the off position. The new settings will be saved and will remain in effect until they are changed again.
revised 4/07
revised 5/08
Summary of Contents for Warrior AXP
Page 2: ......
Page 7: ...FORM NO 56043103 Warrior ST Warrior AXP 5 TECHNICAL SPECIFICATIONS...
Page 27: ...FORM NO 56043103 Warrior ST Warrior AXP 25 FIGURE 2 SCRUB SYSTEM...
Page 29: ...FORM NO 56043103 Warrior ST Warrior AXP 27 NOTES...
Page 31: ...FORM NO 56043103 Warrior ST Warrior AXP 29 FIGURE 4 SCRUB SYSTEM...
Page 57: ...FORM NO 56043103 Warrior ST Warrior AXP 55 FIGURE 4...
Page 59: ...FORM NO 56043103 Warrior ST Warrior AXP 57 FIGURE 5 ELECTRICAL SYSTEM revised 5 08 AXP MODELS...
Page 65: ...FORM NO 56043103 Warrior ST Warrior AXP 63 FIGURE 6 ELECTRICAL SYSTEM revised 5 08 AXP Models...
Page 76: ...74 FORM NO 56043103 Warrior ST Warrior AXP THIS PAGE IS INTENTIONALLY BLANK...
Page 86: ......