70
- FORM NO. 56043103 - Warrior
™
ST, Warrior
™
AXP
ELECTRICAL SYSTEM
MAIN CONTROL PROGRAMMING OPTIONS (CONTINUED)
Regular Scrub Setting Adjustment:
FACTORY DEFAULT: SCRUB PRESSURE =1, SOLUTION = ONE BAR(#1), CHEMICAL = 0 (IF AVAILABLE).
The regular scrub pressure, solution rate and chemical rate can be programmed depending on its application where high solution rate is need with regular scrub
pressure or low solution rate with heavy scrub pressure. To change scrub pressure setting, solution rate setting and chemical setting, perform the following steps:
AXP™ models:
1
Turn the main power key switch to the off position.
2
Press and hold the scrub on and the wand switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold the both switches until the wand indicator and regular scrub indicator turn green.
5
Release both switches. The display will now show the cylinder deck icon with current scrub pressure setting. Scrub off indicator will turn red and regular scrub
indicator will turn yellow.
6
Pressing scrub on switch will now select new scrub pressure. Pressing scrub off switch will save the new setting and move to solution rate setting.
7
The display will now show solution icon with gauge. The regular scrub indicator will now turn green and solution indicator will turn yellow. Pressing solution
switch will now select new solution rate. Pressing scrub off switch will save the new setting and move to chemical setting (If available).
8
The display will now show chemical bottle with current chemical setting. Solution indicator will turn green and chemical indicator will turn green. Pressing
chemical switch will now select new chemical setting. Pressing scrub off switch will save the new setting and display key switch icon on display.
9
Turn the main power key switch to the off position.
10 The new settings will be saved and will remain in effect until they are changed again.
ST models:
1
Turn the main power key switch to the off position.
2
Press and hold the scrub on and the wand switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold both switches until the wand indicator and the regular scrub indicator turn green.
5
Release both switches. The LED display will show the number of the current scrub pressure setting, the scrub off indicator will turn red and the regular scrub
indicator will turn yellow.
6
Press the scrub on switch to select the new scrub pressure.
7
Press the scrub off switch to save the new scrub pressure setting and move to the solution rate setting. The solution
fl
ow indicator will display the number of
bars corresponding to the current solution
fl
ow setting, the regular scrub indicator will turn green and solution indicator will turn yellow.
8. Press the solution switch to select new solution
fl
ow rate.
9
Press the scrub off switch to save the new setting. The scrub off indicator will turn green.
10 Turn the main power key switch to the off position. The new settings will be saved and will remain in effect until they are changed again.
SCRUB PRESSURE & CURRENT LOAD (AMPS) SPECIFICATIONS CHART
Scrub Mode
Scrub Pressure
Indicator
DECK TYPE
Disc 28”
Cyl. 28”
Disc 32”
Cyl. 32”
Regular Scrub
1 bar(#1)
14 AMPS
22 AMPS
16 AMPS
24 AMPS
Heavy Scrub
2 bars(#2)
22 AMPS
31 AMPS
24 AMPS
33 AMPS
Extreme Scrub
3 bars(#3)
36 AMPS
40 AMPS
38 AMPS
42 AMPS
SOLUTION FLOW RATE CHART
Solution Flow Indicator
Flow Rate
One bar gauge(#1)
.3 g/m
Two bar gauge(#2)
.6 g/m
Three bar gauge(#3)
.9 g/m
CHEMICAL CHART
0
Normal chemical setting
-
10% less than normal chemical setting
+
10% more than normal chemical setting
revised 5/08
Summary of Contents for Warrior AXP
Page 2: ......
Page 7: ...FORM NO 56043103 Warrior ST Warrior AXP 5 TECHNICAL SPECIFICATIONS...
Page 27: ...FORM NO 56043103 Warrior ST Warrior AXP 25 FIGURE 2 SCRUB SYSTEM...
Page 29: ...FORM NO 56043103 Warrior ST Warrior AXP 27 NOTES...
Page 31: ...FORM NO 56043103 Warrior ST Warrior AXP 29 FIGURE 4 SCRUB SYSTEM...
Page 57: ...FORM NO 56043103 Warrior ST Warrior AXP 55 FIGURE 4...
Page 59: ...FORM NO 56043103 Warrior ST Warrior AXP 57 FIGURE 5 ELECTRICAL SYSTEM revised 5 08 AXP MODELS...
Page 65: ...FORM NO 56043103 Warrior ST Warrior AXP 63 FIGURE 6 ELECTRICAL SYSTEM revised 5 08 AXP Models...
Page 76: ...74 FORM NO 56043103 Warrior ST Warrior AXP THIS PAGE IS INTENTIONALLY BLANK...
Page 86: ......