DUST AND DEBRIS COLLECTION SYSTEM
SERVICE MANUAL
ENGLISH
Terra™ 5200
1463546000(1)2008-07
45
FILTER SHAKER OPERATION CHECK
During machine operation, when the panel filter is supposed to be clogged, turn off the vacuum system with the switch (6),
1.
then press the filter shaker switch (6) and check that the typical noise is audible. Restart the machine and check that the filter
has been properly shaken. If so, this should result in an appreciable improvement in the machine vacuum capability.
If necessary, check or replace the filter shaker motor, as shown below.
2.
FILTER SHAKER MOTOR REMOVAL
Drive the machine on a level floor and engage the parking brake with the pedal and the lever (25 and 18).
1.
Turn the ignition switch (17) to “0”.
2.
Open the hood (49) and fasten it with the support rod (63).
3.
Disconnect the battery connector (52); keep the hood open.
4.
Disconnect the vacuum system motor connector (57).
5.
Release the fasteners (A) and remove the vacuum system motor cover (B).
6.
Disconnect the electrical connector (C) from the filter shaker.
7.
Remove the filter shaker support frame fastening handwheels (D).
8.
Remove the filter shaker support frame (E).
9.
At the workbench, remove the nuts (F) and the two collars (G).
10.
Recover the filter shaker motor (H).
11.
Assemble the components in the reverse order of disassembly.
12.
A
A
A
B
P100225
S300551
F
G
H
S300556
Summary of Contents for Terra 5200 B
Page 1: ...TerraTM 5200 B SERVICE MANUAL Advance model 9084513010 1463546000 1 2008 07...
Page 2: ......
Page 88: ...ENGLISH SERVICE MANUAL 86 1463546000 1 2008 07 Terra 5200...
Page 100: ...ENGLISH SERVICE MANUAL 98 1463546000 1 2008 07 Terra 5200...
Page 102: ...ENGLISH SERVICE MANUAL 100 1463546000 1 2008 07 Terra 5200...