ENGLISH
INSTRUCTIONS FOR USE
20
SW5500 - 1467284000
09/2016
BATTERY INSTALLATION/REMOVAL AND BATTERY TYPE SETTING (WET OR GEL-AGM)
WARNING!
Do not tilt the lead batteries (WET) to prevent the highly corrosive acid from leaking out of the batteries. Do not
connect, not even accidentally, the battery positive and negative terminals by using tools, keys, etc. This could
cause dangerous short-circuits.
Battery Installation
For approved battery types, see the Technical Data paragraph.
According to the battery dimensions, check if it is possible to
place them inside the relevant plastic container, supplied with
the machine.
If the batteries are larger than the container, use the square
guides, supplied with the machine, to ensure the stability inside
the battery compartment.
WARNING!
Non-sealed WET batteries always need an
appropriate container to prevent the acid form
leaking.
Do not install the WET batteries without an
appropriate container.
1. Engage the parking brake.
2. Check that the ignition key (51) has been removed.
3. Open the battery compartment hood (19) and fasten it with
the support rod (47).
4. Disconnect the battery connector (45).
5. With the help of an appropriate hoisting system, install the
batteries (42).
6. Connect the batteries according to one of the diagrams
shown in figure 2, on the basis of their type.
7. Connect the battery connector (45).
8. Set the battery type (WET or GEL-AGM), according to the
following procedure.
Battery Setting (WET or GEL-AGM)
1. Start the machine by turning the ignition key (51) to “I”,
while holding down push-buttons (52) and (53).
2. Enter the “Parameters” menu by pressing the push-button
(60).
3. Scroll through the parameters by repeatedly pressing the
push-button (60) until you reach the “BATTERY TYPE”
parameter
4. If necessary, change the setting using push-buttons (58)
and (59).
BATTERY
PLUG
6V
6V
6V
6V
BATTERY
PLUG
24V
P100896
Figure 2
Battery Removal
1. Engage the parking brake.
2. Remove the ignition key (51).
3. Open the battery compartment hood (19) and fasten it with the support rod (47).
4. Disconnect the battery connector (45).
5. Disconnect the battery wiring harness (42).
6. Remove any square guide or bracket fastening the batteries.
7. Check that WET battery caps (43) are closed, to prevent the highly corrosive acid from leaking out of the batteries.
8. With the help of an appropriate hoisting system, remove the batteries (42).
1467284000(B)04-2018.indb 20
10/04/2018 12:19:52
Summary of Contents for SW5500
Page 2: ......
Page 36: ...ENGLISH INSTRUCTIONS FOR USE 34 SW5500 1467284000 09 2016...
Page 70: ...FRAN AIS INSTRUCTIONS D UTILISATION 34 SW5500 1467284000 09 2016...
Page 92: ...ESPA OL INSTRUCCIONES DE USO 22 SW5500 1467284000 09 2016...
Page 101: ...INSTRUCCIONES DE USO ESPA OL 1467284000 SW5500 31 09 2016 G H I P100915 Figura 21...
Page 104: ...ESPA OL INSTRUCCIONES DE USO 34 SW5500 1467284000 09 2016...
Page 138: ...PORTUGU S INSTRU ES DE USO 34 SW5500 1467284000 09 2016...
Page 139: ......