     NOTE

Rack mount brackets are a default accessory with the unit; spare brackets can be ordered through ADTRAN, part number: 1700519F1.

Figure 4. Attaching Brackets to the Rack Post

Mounting on a Desk or Shelf

To mount the switch on a desk or shelf, complete the following steps.

1. Verify that the desk or shelf is sturdy enough to support the switch. 
2. Attach the four adhesive rubber feet to the bottom of the switch.

Figure 5. Attaching the Rubber Feet

f

     

CAUTION!

Desk or shelf mounting of the equipment should be such that the amount of air flow required for safe operation of the equipment is not compromised. Allow 1-inch 

clearance on the top and sides of the unit for sufficient air flow.

Connect AC Power

To connect the AC power cord to the switch, complete the following steps.

1. Connect the AC power cord to the AC power receptacle on the rear panel of the switch. 
2. Connect the other end of the AC power cord to a properly grounded AC power outlet. The AC branch circuit socket-outlet must be installed near the 

equipment and must be easily accessible.

Summary of Contents for NetVanta 1560-48-370W

Page 1: ...er cord DB 9 to RJ 45 cable Micro USB to USB cable Four adhesive rubber feet Mounting kit two brackets and eight screws Quick Start f CAUTION The NetVanta 1560 48 370W is intended for indoor use only...

Page 2: ...r on a desk or shelf Mounting in a 19 inch Rack To mount the switch into a 19 inch rack complete the following steps 1 Attach the mounting brackets to both sides of the chassis Insert the provided scr...

Page 3: ...gure 5 Attaching the Rubber Feet f CAUTION Desk or shelf mounting of the equipment should be such that the amount of air flow required for safe operation of the equipment is not compromised Allow 1 in...

Page 4: ...equipment incorporates double pole neutral fusing If the neutral fuse opens and the line fuse does not open voltage could still be present in the unit Install SFP Modules You can install or remove an...

Page 5: ...an also skip Steps 1 2 by pressing WinKey R and typing the ncpa cpl command to get to Step 4 directly Right click on your local adapter and select Properties In the Local Area Connection Properties me...

Page 6: ...e following section describes the three types of LEDs SYSTEM Status LED The SYSTEM Status LED indicates if the switch is powered up correctly or if a system alarm has been triggered for troubleshootin...

Page 7: ...through the switch user interface Task Press for System LED Behavior Port Status LED Behavior Change LED Mode 0 2 seconds Solid Green LED status will change according to the mode selected Reset the Sw...

Page 8: ...1 1 Classification of environmental conditions Storage 1 2 ETSI EN 300 019 1 2 Classification of environmental conditions Transportation Class 2 3 ETSI EN 300 019 1 3 Classification of environmental c...

Reviews: