![ADTRAN NetVanta 1235P Hardware Installation Manual Download Page 24](http://html1.mh-extra.com/html/adtran/netvanta-1235p/netvanta-1235p_hardware-installation-manual_2855163024.webp)
Unit Installation
NetVanta 1235P Hardware Installation Guide
24
Copyright © 2013 ADTRAN, Inc.
61700595G10-34A
Figure 3. NetVanta 1235P ActivReach Switch Wallmount Installation
Instructions for Wall Mounting the NetVanta 1235P ActivReach Switch
Step
Action
1
Remove the mounting brackets. Rotate them 90 degrees so that the portion of the bracket with
the mounting holes is flush with the bottom of the chassis. Reattach the mounting brackets to
the chassis (see
Figure 3
).
2
Decide on a location for the NetVanta. The NetVanta 1235P ActivReach switch is mounted with
the front panel facing down as shown in
Figure 3
. Keep in mind that the unit needs to be
mounted at or above eye level so that the LEDs are viewable.
3
Prepare the mounting surface by attaching a board (typically plywood, 3/4-inch to 1-inch thick)
to a wall stud using #6 to #10 (2.5-inch or greater in length) wood screws.
Important! Mounting to a stud ensures stability. Using sheetrock anchors may not provide
sufficient long-term stability.
4
Have an assistant hold the unit in position as you install two #6 to #10 (1 inch or greater in
length) wood screws through the unit’s brackets and into the mounted board (see
Figure 3
).
5
Proceed to the steps given in
Supplying Power to the Unit on page 25
.
AC INPUT
RPS - 12VDC
EPS - 50VDC