NetVanta 1235P Hardware Installation Guide
Unit Installation
61700595G10-34A
Copyright © 2013 ADTRAN, Inc.
23
Wall Mounting the NetVanta 1235P Units
By following these instructions exactly, the NetVanta 1235P units can be safely mounted on the wall. For
instructions on wall mounting the NetVanta 1235P unit, see the table and
Figure 3 on page 24
.
Rack Mounting the NetVanta Using the Rack Mounting Brackets
Step
Action
1
Install the mounting brackets on the NetVanta. To avoid damaging the unit, use only the screws
included in the shipment when attaching mounting brackets to the chassis.
2
To allow proper grounding, scrape the paint from the rack around the mounting holes where the
NetVanta will be positioned.
3
Position the NetVanta in a stationary equipment rack. This unit occupies 1U of space.
4
Have an assistant hold the unit in position as you install two mounting bolts through the unit’s
brackets and into the equipment rack using a #2 Phillips-head screwdriver.
5
Apply power to the unit (refer to
Supplying Power to the Unit on page 25
).
•
To avoid damaging the unit, use only the screws included in the shipment when
attaching mounting ears to the chassis.
•
When wall mounting the NetVanta, care must be taken not to damage the power cord.
Do not attach the power cord to the building surface or run it through walls, ceilings,
floors, or openings in the building structure.
•
The socket-outlet must be installed near the equipment and must be easily accessible.