ISU 2x64 Dual Port ISDN Service Unit User Manual
27
Chapter 6
Configuration
DIAL LINE OPERATION
This section explains how to configure the ISU 2x64 when using
ISDN Basic Rate switched service. Figure 6-3 illustrates the entire
menu tree.
The following are step-by-step procedures for configuring the
unit for dial line operation, switch protocol, call type, terminal ID,
dial options, auto answer, answer tone, connect timeout, call
screening, and SBus termination.
To dial calls over the ISDN, the unit must be configured for
Dial
Line
. The menu path to select Dial Line operation is shown in Fig-
ure 6-1.
Figure 6-1
Dial Line Menu Tree
When using a VT 100 terminal, press
Ctrl + C
to access the Con-
figuration screen, then set the
Line type
option to
Dial Line
. The
screen appears as shown in Figure 6-2.
3=CONFIG
1=Netw. options
2=DTE options
3=Protocol
4=Quick setup
5=Security
6=Remote Config
1=Dial Line
2=Leased Line
Summary of Contents for ISU 2x64
Page 14: ...List of Tables viii ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1 1D...
Page 44: ...Chapter 6 Cofiguration 30 ISU 2x64 Dual Port ISDN Service Unit User Manual...
Page 86: ...Chapter 8 Quick Setup 72 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1 1D...
Page 102: ...Chapter 11 Specifications 88 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1 1D...
Page 108: ...Appendix A AT Commands 94 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1 1D...
Page 132: ...Appendix D S Register List 118 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1 1D...
Page 158: ...Glossary 144 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1 1D...
Page 164: ...Index 150 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1 1D...