HDSL 3192 HTU-C Installation and Maintenance Practice
10
61247004L1-5A
PROVISIONING
Upon initial installation, the 3192 HTU-C is provisioned according to the factory default
settings. The provisioning settings can be viewed and manipulated through management
access via the front panel RS-232 port.
lists the available provisioning options and
their factory default settings.
Table 7. 3192 HTU-C Provisioning Defaults
Option
Settings
Default
DSX-1 Line Buildout
0-133 feet; 133-266 feet; 266-399 feet;
399-533 feet; 533-655 feet
0-133 feet
DSX-1/DS1 Line Code
B8ZS; AMI
B8ZS
DSX-1/DS1 Framing
Auto; ESF; SF; Unframed;
Forced Conversion
Auto
NIU Loopback
Enabled; Disabled
Enabled
New England 1:6 LPBK
Disabled; Enabled
Disabled
Loopback Timeout
None; 60 Min.; 120 Min.
120 Min.
Customer Loss Response
AIS; CDI; Loopback
AIS
Latching Loopback Mode
T1; FTI
T1
PRM Mode
None; NPRM; SPRM
None
DS1 TX Level
0 db; –15 db
0 db
HTUC Shelf Alarm
Enabled; Disabled
Disabled
Span Power
Enabled; Disabled
Enabled
DS0 Blocking
None blocked;
Any of 01-24 blocked or unblocked
None blocked