Quick Start

D

ESCRIPTION

This Quick Start provides instructions for the installation of the 
GPON TA352/TA374 Optical Network Termination (ONT) units (P/N: 
1287802F1C, 1287803F1C). The GPON TA352 4th Gen ONT has two 
POTS ports and two Gigabit Ethernet ports; the GPON TA374 2nd Gen 
ONT has four POTS ports and four Gigabit Ethernet ports.

The ONTs are enclosed in a weather-hardened Network Interface Device 
(NID) which mounts to the exterior of a building. The figure below 
illustrates the TA374 ONT in the context of the NID with the access door of 
the NID removed.

Figure 1. Example NID Enclosure

 The ONT is a Class 1 Laser Product. 

I

NSTALLATION

This section explains NID installation and all cable routing.
After unpacking the ONT, inspect it for damage. If damage is noted, file a 
claim with the carrier and then contact ADTRAN. For more information, 
refer to the warranty.

ONT

Part Number

TA 352 4th Gen Exterior Wall Mount Outdoor ONT

1287802F1C

TA 374 2nd Gen Exterior Wall Mount Outdoor ONT

1287803F1C

ETH 1

ETH 2

ETH 3

ETH 4

POTS 3

POTS 4

POTS 2 POTS 3 POTS 4

POTS 1

TA 374 2nd GEN
1287803F1C

TIP

RING

ETH 1

ETH 2

ETH 1

ETH 2

12V     , 1.25A

POTS 2

POTS 1

POWER

GPON

POTS 2

POTS 1

TELCO ACCESS ONLY

TELEPHONE TROUBLESHOOTING
1. Identify the bad line.
2. Disconnect the plug from the appropriate POTS jack and plug
    any working telephone into that jack.
      • If the telephone works, there is a problem inside the house.
         Take necessary steps to repair problem before reconnecting POTS jack.
      • If the telephone does not work, contact your service provider.
3. Remove the telephone and replace the plug into the POTS jack.
4. Close the unit.

This device complies with Part 15 of the FCC rules. Operation is subject to 
the following two conditions:
     • This device may not cause harmful interference
     • This device must accept any interference received, including  
       interference that may cause undesired operation.

CLASS 1 LASER 

PRODUCT

ACCESSORY

COMMUNICATION

SERVICE EQUIPMENT

E187790

901 Explorer Blvd.

Huntsville, AL 35806 USA

www.adtran.com

CLASS 1 LASER
PRODUCT

f

     

WARNING!

Read all warnings and cautions before installing or servicing this 
equipment.

Refer to the national, state and local electrical codes for the 
requirements for power, grounding, wiring, and installation methods.

The protective earth (PE) ground screw of this device must be properly 
tightened to the grounding post of the Network Interface Device (NID). 
The PE terminal of the NID must be properly grounded utilizing a 6 
AWG (13.3 mm²) ground wire.

This equipment must be serviced by authorized service personnel 
only. All repair procedures are detailed to allow 
sub-assembly repairs ONLY. Authorized service personnel should not 
attempt component level repairs or circuit modifications to the printed 
circuit board. Improper repairs can create a safety hazard.

f

     

CAUTION!

The buried fiber drop cable to the subscriber’s premise used in this 
application must be a UL Listed non-metallic armored cable 
containing no other electrically conductive materials.

Required Tools and Supplies

In addition to standard technician tools, the following tools are required for 
this installation:

Carpenter’s level

3/32 inch screw driver for connecting ONT power

5/32 inch hex tamper proof bit

Two #10 screws (Max. Head Diameter 0.385”) and appropriate wall 
anchors for mounting the NID

RJ-11 and RJ-45 crimpers

A telephony/data communication test set

Assorted tie wraps for securing cabling and wiring

Up to 4 RJ-45 and RJ-11 plugs

For fiber optic connections, you must have the following tools:

PON power meter with wavelength filtering

Fiberscope or videoscope

Fiber optics Fusion splicing tools

Fiber connector cleaning tool

SC/APC fiber connector

Included with the GPON TA352/TA374 packaging are 2/4 Two-screw 
Terminal Bridges (2 for the TA352 and 4 for the TA374), an SC/APC fiber 
jumper, and a 7-position power and alarm connector. For data, the 
connection to the ONT is through the RJ-45 Ethernet connectors

For 

POTS, the connection is made through the 2/4 Two-screw Terminal 
Bridges.

Installation Steps

To install the ONT, complete the following steps:

“Mount the NID Enclosure”

“Ground the NID”

“Install the ONT”

“Route the Fiber Connection”

“Connect Power/Alarm”

“Install a Local Power Source”

Total Access

GPON TA352/TA374

Exterior Wall Mount ONT

May 2021

61287802F1C-13A

Summary of Contents for GPON TA352

Page 1: ...G Read all warnings and cautions before installing or servicing this equipment Refer to the national state and local electrical codes for the requirements for power grounding wiring and installation methods The protective earth PE ground screw of this device must be properly tightened to the grounding post of the Network Interface Device NID The PE terminal of the NID must be properly grounded uti...

Page 2: ...stall the ONT in the NID Housing align the hinges on the ONT with the mounting points on the NID Housing and snap the two together refer to Figure 5 g NOTE Figure 5 shows the TA374 ONT which has 4 two screw terminal bridges POTS1 to POTS4 only 2 shown in Figure 12 and 4 Ethernet connections ETH1 to ETH4 The TA352 has two POTS ports POTS1 POTS2 and two Gigabit Ethernet ports ETH 1 ETH 2 Ground Bar ...

Page 3: ...epair problem before reconnecting POTS jack If the telephone does not work contact your service provider 3 Remove the telephone and replace the plug into the POTS jack 4 Close the unit This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including inte...

Page 4: ...PS output Installation of the Local Power Source will be dictated by on site conditions and local telephone company practices f CAUTION To reduce the risk of fire use minimum no 26 AWG telecommunications line cord Install the UPS Installation of the Uninterruptible Power Source UPS will be dictated by on site conditions and local telephone company practices Refer to the installation material that ...

Page 5: ...terference to radio communications ans is in violation of the FCC Rules part 15 CLEI TEL NUMBER PWR GPON POTS1 POTS2 POTS3 POTS4 Ethernet Connections POTS Connections Two Post Bridge POTS and Ethernet Captive Screw 4 Tie wrap both the POTS and Ethernet cables to the NID housing near the cable entry point LED STATUS The LED table below provides the LED status for the ONT REGISTRATION ID There are t...

Page 6: ...er to the warranty for further information Field support for software is provided through upgrade facilities SAFETY AND REGULATORY Refer to the Safety and Regulatory Notice for this product P N 61287802F1C 17 for detailed safety and regulatory information Consultez l avis sur la sécurité et la conformité à la réglementation pour ce produit 61287802F1C 17 pour obtenir des renseignements détaillés s...