Section 61104020L4-5, Issue 3

61104020L4-5C

4. Depress the recessed TEST pushbutton to initiate

the test.  The TEST LED will illuminate GREEN
and the ERR LED should go out following
synchronization to the test pattern from the far
end.

5. If the far end unit is a U-BR1TE V using the

internal  2047 test pattern, perform steps 1
through 4, choosing the same front panel switch
setting.  If the far end is a test set, ensure it is
configured for a 2047 test pattern.

6. To insert one bit error, momentarily (for less than

two seconds) depress the TEST pushbutton.  Bit
errors will be seen at the far end test unit.

7. To deactivate the loopback, depress the TEST

pushbutton for two seconds, until the GREEN
TEST LED is extinguished, or select NORM on
the NORM/PTRN DIP switch.  Upon deactivation
of the test, the TEST LED will go out.

To initiate a point-to-point test using an external DS0
digital test set, perform the following:

1. Insert the TX and RX bantam plug of the DS0

digital test set into the U-BR1TE V respective
front panel bantam jacks.  Connect the clock
input of the DS0 digital test set to the channel
banks clock source (D4’s OIU, or the SLC-96
SSU).  Configure the test set for Near Logic and
64 kbps.

2. Select the desired test direction, LPTX or CRTX,

using the ten-position rotary switch.  Refer to
Table 2.

3. Select the desired bearer channel using the B1/B2

DIP switch.

4. Depress the recessed TEST pushbutton to initiate

the test.  The TEST LED will illuminate
YELLOW.

5. If the far end unit is a U-BR1TE V using a DS0

digital test set, perform steps 1 through 4,
choosing the same front panel switch setting.
Ensure that both test sets are configured for the
same test pattern (511, 2047).  If the far end unit
is a U-BR1TE V using the internal 2047 test
pattern, perform steps 1 through 4 of the previous
section.

6. Observe the DS0 digital test set for bit errors.

7. To deactivate the loopback, depress the TEST

pushbutton, or remove the transmit bantam plug.
Upon deactivation of the test, the TEST LED will
go out.

Local Loopback (LPBK)

A bilateral loopback can be initiated from the
U-BR1TE V front panel for either bearer channel.  A
local test pattern source is not required for this test.
To initiate a local loopback, perform the following:

1. Select the desired bearer channel using the B1/B2

DIP switch.

2. Select LPBK using the ten-position rotary switch.

See Table 2.

3. Depress the recessed TEST pushbutton to initiate

the test.  The TEST LED will illuminate
YELLOW.

4. To deactivate the loopback, depress the TEST

pushbutton.  Upon deactivation of the test, the
TEST LED will go out.

Local Performance Monitoring

Performance Monitoring of the local T1 carrier system
and 2-wire U-interface of the ISDN data can be
performed from the front panel without interruption of
service to the customer.  For this test, bearer channel
selection is not applicable and a test pattern source is
not required.  To initiate a local performance
monitoring session, perform the following:

1. Ensure the NORM/PTRN DIP switch is in the

NORM position, and that a bantam plug is NOT
installed in the front panel TX bantam jack.

2. Select ADR1 using the ten-position rotary switch.

3. Depress the recessed TEST pushbutton to initiate

the test.  The TEST LED will illuminate GREEN.

4. The  total number of Near End Block Errors

(NEBE) received are simultaneously displayed as
crc errors with the LP and CR CRC status LEDs.
(See Table 3).

5. To exit local performance monitoring, depress

the TEST button for two seconds or longer.
Upon deactivation of the test, the TEST LED will
go out.

Summary of Contents for D4 U-BR1TE V

Page 1: ...cations Clear channel capability B8ZS is not required of the T1 facility if zero byte substitution is enabled The U BR1TE V plugs into a single channel slot of the D4 bank but can require three time s...

Page 2: ...es three time slots In a D4 or SLC 96 Mode III channel bank it occupies the time slot associated with the physical channel slot that it occupies plus the next two time slots to the right The physical...

Page 3: ...d D only occupies only the two time slots associated with the physical slot used In this configuration option the unit for Slot 1 4 7 or 10 Figure 2 Backplane Pin Assignments 28 29 30 31 32 33 34 35 3...

Page 4: ...of the U BR1TE V Figure 5 SW1 SW3 and SW6 Labeling 1 TRM B1 B2 D ZBS DIS 1 O N 2 2 3 4 5 6 O N ZBS EN LUNT COT 1 TRM B1 B2 D ZBS DIS 2 3 4 5 6 O N ZBS EN 1 O N 2 LUNT COT SW1 SW3 TANDEM LULT RT ADJ T...

Page 5: ...s e b d l u o h s h c t i w s s i h T s i h T n o i t a r u g i f n o c e c r u o S e c i f f O m e d n a T r o r e m o t s u C o t t n e c a j d A r e t a e p e R U e c i f f O m e d n a T d n a h c...

Page 6: ...n Switch Settings at Network Locations for ISDN Applications 2 Wire 2 Wire T1 2 Wire 2 Wire T1 2 Wire T1 2 Wire 2 Wire T1 ISDN Switch D4 Channel Bank Customer NT1 D4 SLC 96 RT Channel Bank Adjacent to...

Page 7: ...a l F Testing will flash yellow when BER 10 6 is e e s g n i r o t i n o M 0 1 R E B a n e h w w o l l e y e t a n i m u l l i d n a d e t c e t e d 5 d e t c e t e d s i R C s u t a t S r e i r r a C...

Page 8: ...anging the selector knob to the desired address It is not necessary to exit the test mode to select a new address 7 To deactivate the loopback depress the TEST pushbutton for two seconds until the GRE...

Page 9: ...attern 511 2047 If the far end unit is a U BR1TE V using the internal 2047 test pattern perform steps 1 through 4 of the previous section 6 Observe the DS0 digital test set for bit errors 7 To deactiv...

Page 10: ...the in band DDS loopback commands The U BR1TE V responds to latching loopback sequences for the DS0 DP The U BR1TE V allows the OCU loopback command to pass in band downstream to the IDSL OCU R Upon...

Page 11: ...and CSU latching loopbacks 1 Minimum of 35 transition in progress TIP bytes X0111010 2 Minimum of 35 loopback select code LSC bytes DS0 DP X0000101 OCU X1010101 CSU X0110001 3 Minimum of 100 loopback...

Page 12: ...the U BR1TE toward the customer See Figure 10 This allows data to be sent from the remote end to test the local loop and the OCU R This loopback is indicated by a flashing CUST LBK LED on the IDSL OC...

Page 13: ...rvices to ISDN equipment By using the 2 wire ISDN interface for 128 kbps data rate the U BR1TE V Leased Mode Operation allows pair savings over traditional DDS deployment DDS Frame Relay support allow...

Page 14: ...sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256...

Reviews: