ADTRAN D4 U-BR1TE V Installation And Maintenance Manual Download Page 12

12

Section 61104020L4-5, Issue 3

61104020L4-5C

Performance Monitoring

Local Performance Monitoring is available only for
the U-interface, when configured for a leased mode of
operation.  See the subsections entitled 

Loopback

Tests, Point-to-Point Test

, and 

Local Loopback

 for

applicable test descriptions.

ADTRAN U-BR1TE Bidirectional Loopback

In LULT Mode, the ADTRAN U-BR1TE will execute
a bidirectional loopback when performing DS0 DP
loopback.  See 

Figure 9

 for an illustration of the

bidirectional loopback.

Remote End Initiated LBK Tests

The U-BR1TE supports loopbacks generated from the
remote unit which allows testing to be performed

without coordination with the CO or test center.
Loopbacks initiated by the OCU-R front panel LBK
pushbutton aid in system turn up testing or
troubleshooting from the remote end.

The U-BR1TE responds to a loopback command
initiated at the OCU-R as follows:

Pressing the OCU-R LBK pushbutton on the OCU-R
once will initiate a loopback at the U-BR1TE toward
the customer.  See 

Figure 10

.  This allows data to be

sent from the remote end to test the local loop and the
OCU-R.  This loopback is indicated by a flashing
CUST LBK LED on the IDSL OCU-R and a solid
LBK LED on the U-BR1TE.

Pressing the OCU-R LBK pushbutton a second time
will initiate a loopback at the OCU-R toward the
4-wire DDS (CPE) interface.  A solid CUST LBK
LED on the IDSL OCU-R indicates a loopback at the
IDSL OCU-R toward the customer equipment.
See 

Figure 11

.  Pressing the OCU-R LBK pushbutton

a third time disables all current latching loopbacks
initiated by the OCU-R LBK pushbutton.

If errors exist the loopbacks can help determine the
source; either the local loop or the OCU-R.

Test Set

IDSL OCU-R

ADTRAN U-BR1TE

Bidirectional 

loopback

Figure 9. ADTRAN U-BR1TE Bidirectional

Loopback

Figure 11.  IDSL/DDS Remote End Initiated Loopback, Customer Loop

4-Wire

CPE Interface

OCU-R

Push twice for

OCU-R  Loopback

Local Loop

ASC 9Eh

U-BR1TE

Loopback
Pushbutton

Test

Set

ASC 9Eh

Figure 10.  IDSL/DDS Remote End Initiated Loopback, Local Loop

4-Wire

CPE Interface

OCU-R

Push once for

U-BR1TE Loopback

Local Loop

ASC 9Eh

U-BR1TE

Loopback
Pushbutton

Test

Set

Summary of Contents for D4 U-BR1TE V

Page 1: ...cations Clear channel capability B8ZS is not required of the T1 facility if zero byte substitution is enabled The U BR1TE V plugs into a single channel slot of the D4 bank but can require three time s...

Page 2: ...es three time slots In a D4 or SLC 96 Mode III channel bank it occupies the time slot associated with the physical channel slot that it occupies plus the next two time slots to the right The physical...

Page 3: ...d D only occupies only the two time slots associated with the physical slot used In this configuration option the unit for Slot 1 4 7 or 10 Figure 2 Backplane Pin Assignments 28 29 30 31 32 33 34 35 3...

Page 4: ...of the U BR1TE V Figure 5 SW1 SW3 and SW6 Labeling 1 TRM B1 B2 D ZBS DIS 1 O N 2 2 3 4 5 6 O N ZBS EN LUNT COT 1 TRM B1 B2 D ZBS DIS 2 3 4 5 6 O N ZBS EN 1 O N 2 LUNT COT SW1 SW3 TANDEM LULT RT ADJ T...

Page 5: ...s e b d l u o h s h c t i w s s i h T s i h T n o i t a r u g i f n o c e c r u o S e c i f f O m e d n a T r o r e m o t s u C o t t n e c a j d A r e t a e p e R U e c i f f O m e d n a T d n a h c...

Page 6: ...n Switch Settings at Network Locations for ISDN Applications 2 Wire 2 Wire T1 2 Wire 2 Wire T1 2 Wire T1 2 Wire 2 Wire T1 ISDN Switch D4 Channel Bank Customer NT1 D4 SLC 96 RT Channel Bank Adjacent to...

Page 7: ...a l F Testing will flash yellow when BER 10 6 is e e s g n i r o t i n o M 0 1 R E B a n e h w w o l l e y e t a n i m u l l i d n a d e t c e t e d 5 d e t c e t e d s i R C s u t a t S r e i r r a C...

Page 8: ...anging the selector knob to the desired address It is not necessary to exit the test mode to select a new address 7 To deactivate the loopback depress the TEST pushbutton for two seconds until the GRE...

Page 9: ...attern 511 2047 If the far end unit is a U BR1TE V using the internal 2047 test pattern perform steps 1 through 4 of the previous section 6 Observe the DS0 digital test set for bit errors 7 To deactiv...

Page 10: ...the in band DDS loopback commands The U BR1TE V responds to latching loopback sequences for the DS0 DP The U BR1TE V allows the OCU loopback command to pass in band downstream to the IDSL OCU R Upon...

Page 11: ...and CSU latching loopbacks 1 Minimum of 35 transition in progress TIP bytes X0111010 2 Minimum of 35 loopback select code LSC bytes DS0 DP X0000101 OCU X1010101 CSU X0110001 3 Minimum of 100 loopback...

Page 12: ...the U BR1TE toward the customer See Figure 10 This allows data to be sent from the remote end to test the local loop and the OCU R This loopback is indicated by a flashing CUST LBK LED on the IDSL OC...

Page 13: ...rvices to ISDN equipment By using the 2 wire ISDN interface for 128 kbps data rate the U BR1TE V Leased Mode Operation allows pair savings over traditional DDS deployment DDS Frame Relay support allow...

Page 14: ...sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256...

Reviews: