ADTRAN D4 U-BR1TE V Installation And Maintenance Manual Download Page 1

1

Section 61104020L4-5, Issue 3

61104020L4-5C

1. GENERAL

This practice provides installation and maintenance
procedures for the ADTRAN D4 U-BR1TE V w/PWR
and DDS Loopbacks, P/N 1104020L4.  

Figure 1

 is an

illustration of the U-BR1TE V.

ISDN/DDS

The U-BR1TE employs features for  both ISDN and
DDS transport.  ISDN comprises the major
functionality and is described in this section.  A
description of DDS functionality is located in
Section 3.

Revision History

Issue 3 of this document includes 2B leased mode
operation and revises the CLEI code.

Section 61104020L4-5C

Issue 3, May 2002

CLEI Code: D4C5BENB_ _

D4 U-BR1TE V w/PWR and DDS Loopbacks

ISDN 2B1Q Interface

Installation and Maintenance

Functional Description

The U-BR1TE V is a line card that plugs into a single
channel slot of an AT&T D4/SLC

®

-96 channel bank.

It provides an ISDN U-interface and allows the
transport of Basic Rate 2B+D information over T1
carriers and twisted pair wiring.  The U-BR1TE V
combines the functionality of a standard U-BR1TE V
and a U-Repeater Powering Module which will
simplify the installation of the U-Repeater.  Span
powering also allows deployment of 2-wire DDS
when an IDSL OCU-R is used to terminate the ISDN
local loop.  This eliminates the need to provide AC
power at the customer premises.

The U-BR1TE V is used at both the Central Office
Terminal and Remote Terminal locations.  Clear
channel capability (B8ZS) is not required of the T1
facility if zero byte substitution is enabled.  The
U-BR1TE V plugs into a single channel slot of the D4
bank, but can require three time slots when
transporting 2B+D information.  Block error rate
performance over the T1 facility is monitored and is
available to the network.

CONTENTS

1.

GENERAL .................................................................. 1

2.

INSTALLATION ....................................................... 2

3.

TESTING .................................................................... 7

4.

MAINTENANCE ..................................................... 13

5.

WARRANTY AND CUSTOMER SERVICE ......... 14

FIGURES

Figure 1. ADTRAN U-BR1TE V ..................................... 1
Figure 2. Backplane Pin Assignments .............................. 3
Figure 3. Time Slot Assignments for 2B+D Service in

SLC Mode I w/ D1D Counting ......................... 3

Figure 4. Time Slots that CANNOT Contain BR1TE

Cards .................................................................. 4

Figure 5. SW1, SW3, and SW6 Labeling ......................... 4
Figure 6. Position Switch Settings at Network Locations

for ISDN Applications ...................................... 6

Figure 7. U-BR1TE V IDSL/DDS Circuit Diagram ...... 10
Figure 8. IDSL/DDS Loopback Response ..................... 11
Figure 9. ADTRAN U-BR1TE Bidirectional Loopback .. 12
Figure 10. IDSL/DDS Remote End Initiated Loopback,

Local Loop ...................................................... 12

Figure 11. IDSL/DDS Remote End Initiated Loopback,

Customer Loop ................................................ 12

Figure 12. IDSL/DDS Trouble Codes .............................. 13
Figure 13. DS0 Latching Loopback ................................. 14

TABLES

Table 1.

SW1, SW3, and SW6 Option Settings ............... 5

Table 2.

Rotary Switch Options ....................................... 7

Table 3.

LED Indication ................................................... 7

Figure 1.  ADTRAN U-BR1TE V

LP

CR

ACT

TEST

ERR

(Rx)

L

O
G

I

C

OUT

(Tx)

IN

U-BR1TE

 

V

D4-UBR1PWR/DDS

1104020L4

B2

TEST

B1

PTRN

NORM

2

1

AD6

AD5

AD4

AD3

AD2

AD1

NT1

LPTX

CRTX

LPBK

SW1

SW2

SW4

SW5

SW3

SW6

Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.

Summary of Contents for D4 U-BR1TE V

Page 1: ...cations Clear channel capability B8ZS is not required of the T1 facility if zero byte substitution is enabled The U BR1TE V plugs into a single channel slot of the D4 bank but can require three time s...

Page 2: ...es three time slots In a D4 or SLC 96 Mode III channel bank it occupies the time slot associated with the physical channel slot that it occupies plus the next two time slots to the right The physical...

Page 3: ...d D only occupies only the two time slots associated with the physical slot used In this configuration option the unit for Slot 1 4 7 or 10 Figure 2 Backplane Pin Assignments 28 29 30 31 32 33 34 35 3...

Page 4: ...of the U BR1TE V Figure 5 SW1 SW3 and SW6 Labeling 1 TRM B1 B2 D ZBS DIS 1 O N 2 2 3 4 5 6 O N ZBS EN LUNT COT 1 TRM B1 B2 D ZBS DIS 2 3 4 5 6 O N ZBS EN 1 O N 2 LUNT COT SW1 SW3 TANDEM LULT RT ADJ T...

Page 5: ...s e b d l u o h s h c t i w s s i h T s i h T n o i t a r u g i f n o c e c r u o S e c i f f O m e d n a T r o r e m o t s u C o t t n e c a j d A r e t a e p e R U e c i f f O m e d n a T d n a h c...

Page 6: ...n Switch Settings at Network Locations for ISDN Applications 2 Wire 2 Wire T1 2 Wire 2 Wire T1 2 Wire T1 2 Wire 2 Wire T1 ISDN Switch D4 Channel Bank Customer NT1 D4 SLC 96 RT Channel Bank Adjacent to...

Page 7: ...a l F Testing will flash yellow when BER 10 6 is e e s g n i r o t i n o M 0 1 R E B a n e h w w o l l e y e t a n i m u l l i d n a d e t c e t e d 5 d e t c e t e d s i R C s u t a t S r e i r r a C...

Page 8: ...anging the selector knob to the desired address It is not necessary to exit the test mode to select a new address 7 To deactivate the loopback depress the TEST pushbutton for two seconds until the GRE...

Page 9: ...attern 511 2047 If the far end unit is a U BR1TE V using the internal 2047 test pattern perform steps 1 through 4 of the previous section 6 Observe the DS0 digital test set for bit errors 7 To deactiv...

Page 10: ...the in band DDS loopback commands The U BR1TE V responds to latching loopback sequences for the DS0 DP The U BR1TE V allows the OCU loopback command to pass in band downstream to the IDSL OCU R Upon...

Page 11: ...and CSU latching loopbacks 1 Minimum of 35 transition in progress TIP bytes X0111010 2 Minimum of 35 loopback select code LSC bytes DS0 DP X0000101 OCU X1010101 CSU X0110001 3 Minimum of 100 loopback...

Page 12: ...the U BR1TE toward the customer See Figure 10 This allows data to be sent from the remote end to test the local loop and the OCU R This loopback is indicated by a flashing CUST LBK LED on the IDSL OC...

Page 13: ...rvices to ISDN equipment By using the 2 wire ISDN interface for 128 kbps data rate the U BR1TE V Leased Mode Operation allows pair savings over traditional DDS deployment DDS Frame Relay support allow...

Page 14: ...sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256...

Reviews: