background image

4

Section 61150070L1-5, Issue 4

61150070L1-5D

A1
A2
A3
A4
A5
A6
A7
A8
A9

A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32

1   FRM GND
2   CCAIN+
3   CCAIN-
4   +5 V 
5   CCBIN+
6   CCBIN-
7   +12 V
8   INCLK
9   GND
10  -48 F
11  RSPV
12  TSPV
13  -48 V
14  YALMA
15  BALMA
16  RALMA
17  YALMB
18  BALMB
19  RALMB
20  TIMCLK
21  GND
22  RFRM
23  RDCLK
24  RPCM
25  GND
26  BCU ALM
27  TREF
28  TFRM
29  TPCM
30  TCLK
31  GND
32  SYSCLK

C1
C2
C3
C4
C5
C6
C7
C8
C9

C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32

65  
66  LOCCK+
67  LOCCK-
68            (MAD0)
69  GND  (MAD1)
70  GND  (MAD2)
71  -12 V
72  
73  GND
74  -48 FRT
75  
76  RREF
77  -48 VRT
78  FRZ
79  BT
80  BR
81  GND
82  GND
83  BT1
84  BR1
85  GND
86  AT
87  AR
88  
89  GND
90  AT1
91  AR1
92  
93  RNDIS
94  TKP
95  GND
96  

J27

Row C

Row A

Figure 3.  Connector Pin Assignments

Remote Loopback

The Remote loopback feature only operates in ESF
mode framing format.  If ESF mode is optioned,
activating the Remote Loopback switch loops the T1
line of the remote bank. See Description Practice,
Section 61150070L1-2, for details of the loopback
sequence.

Faceplate Indicators

The ACT 2300 LIU has 13 faceplate indicators.  The
indicators can be grouped into three categories:
Configuration, Status, and Test. Figure 5 shows
faceplate LEDs and Table 3 describes their meaning.

4. MAINTENANCE

The ACT LIU requires no routine maintenance to
operate properly. In case of equipment malfunction,
use the faceplate test connector and indicators to
determine the trouble source. The faceplate of the
ACT LIU contains the Bantam test jacks for a T1
tester such as a Phoenix 5575 test set.

The MON Bantam test jacks allow a test set to
monitor the T1 data stream without disturbing it. The
FAC Bantam test jacks allow a test set to intercept the
T1 data stream. Figure 4 shows the Bantam test jacks
in the ACT LIU Functional Block Diagram.

Repair services may be obtained by returning the
defective unit to the ADTRAN Repair Department
(see subsection ADTRAN Customer Service).

Figure 4.  ACT LIU Functional Block Diagram

Clock and Data

Recovery

MON IN

Test Jack

DSX-1

RX

PAIR

FAC OUT

Test Jack

Line Format

Decoder

To

ACT

 BCU

To LIU

Controller

RPCM, RCLK, 
RFRM

DSX-1 Receiver Circuitry

DSX-1 Transmitter Circuitry

MON OUT

Test Jack

Local

Loopback

Point

DSX-1

TX

PAIR

FAC IN

Test Jack

From

ACT BCU

Line

Loopback

Point

Payload

Loopback

Point

TPCM, TCLK, 
TFRM

Equalizer

Line Format

Encoder

DJAT

T1

R1

T

R

Summary of Contents for ACT LIU

Page 1: ...tam jacks for testing Front panel indicators showing the status of the unit Front panel DB 9 connector for access to timing signals for testing Figure 1 ADTRAN ACT LIU List 1 Local loop or external timing modes Composite clock output Installs in the ACT 2300 and ACT 1900 channel banks Revision History Issue 4 adds a Note on the T1 interface and updates the document format Description The ADTRAN AC...

Page 2: ...ceplate mounted switch are used to manually provision the unit Switch Option Settings Switch 2 SW2 selects line equalization Payload or Line loopback at the remote bank line code format binary 8 zero substitution B8ZS or alternate mark inversion AMI framing format superframe SF or extended superframe ESF and timing source local loop or external Figure 2 shows the location of SW2 and Table 1 provid...

Page 3: ...rom the T1 line This allows internal bank testing individual card tests and provides a baseline for line testing Table 1 ACT LIU Option Settings n o i t c n u F h c t i w S n o i t c e l e S n o i t i d n o C t a m r o F g n i m a r F 1 2 W S N O F F O F S E e m a r f r e p u S d e d n e t x E F S e m a r f r e p u S t a m r o F e d o C e n i L 2 2 W S N O F F O S Z 8 B g n i d o c e n i l n o i t...

Page 4: ...dicators The ACT 2300 LIU has 13 faceplate indicators The indicators can be grouped into three categories Configuration Status and Test Figure 5 shows faceplate LEDs and Table 3 describes their meaning 4 MAINTENANCE The ACT LIU requires no routine maintenance to operate properly In case of equipment malfunction use the faceplate test connector and indicators to determine the trouble source The fac...

Page 5: ...S Z 8 B s e t a c i d n i N O d e t c e l e s I M A s e t a c i d n i F F O s u t a t S R A d e r a l c e d m r a l A d e R s e t a c i d n i N O Y A d e r a l c e d m r a l A w o l l e Y s e t a c i d n i N O I A d e r a l c e d m r a l A S I A s e t a c i d n i N O M P C L t i n u l a c o l f o R E B e t a r r o r r e t i b s e t a c i d n I 0 1 R E B F F O 5 0 1 R E B N O 5 M P M R t i n u e t ...

Reviews: