Section 61246045L1-5, Issue 2

61246045L1-5B

The unit can detect the loopback activation or
deactivation code sequence 

only

 if an error rate of

1E

-03

 or better is present.

NOTE:

In all control code sequences presented, the
in-band codes are shown leftmost bit
transmitted first, and the ESF data link
codes with rightmost bit transmitted first.

Disarmed State

The disarmed state is the normal mode of operation.
Each HDSL element is transparent to the data flow.
However, the in-band data flow and the ESF data
link are monitored for the arming sequence.

The in-band control code sequence used to
simultaneously arm the loopback capability of all
HDSL elements is the standard 5-bit in-band
sequence used for NIU Smartjack loop-up.  Each
HDSL element arms after receiving the following
code for five seconds:

Arm Sequence

11000

The arming process ensures unambiguous race-free
operation of HDSL element arming and Smartjack
loop-up.  The HDSL unit can detect the sequence
without interfering with the detection by the
Smartjack.  Presently, the Smartjack loop-up
response requires a duration of at least five seconds.
The objective of the HDSL detection scheme is to
arm the HDSL elements without interfering with the
Smartjack loop-up.

The requirement imposed on the arm sequence is
that the Smartjack should loop-up and all HDSL
elements make a transition from the disarmed state
into the armed state.  All other control code
sequences are ignored in the disarmed state.

The ESF data link sequence used to simultaneously
arm the loopback capability of all HDSL elements is
the standard 16-bit ESF data link sequence used for
NIU Smartjack loop-up.

Table A-1.  HDSL Standard Loopback Control Codes

Name

Arming (In-band) ...............................

Arming (ESF) .....................................

Activation  (HTU-C) ..........................

Activation (HRE #1) ..........................

Activation (HRE #2) ..........................

Activation (HTU-R) ...........................

Deactivation (all HDSL elements) ....

Disarming (In-band) ..........................

Disarming (ESF) ................................

Arming Timeout .................................

Loop-up Timeout ...............................

Detection Time

5 Seconds

4 Repetitions

> 4 Seconds

> 4 Seconds

> 4 Seconds

> 4 Seconds

>5 Seconds

5 Seconds

4 Repetitions

2 Hours

Programmable from HTU-C:
None, 20, 60, or 120 minutes

Code

11000 ...............................

0001 0010 1111 1111 .....

1101 0011 1101 0011 .....

1100 0111 0100 0001 .....

1100 0111 0101 0100

1100 0111 0100 0010 .....

1001 0011 1001 0011 .....

11100 ...............................

0010 0100 1111 1111 .....

N/A ..................................

N/A ..................................

Comments

Signal sent in-band or over ESF
data link.  HDSL elements in
disarmed state make transition to
armed state.  Detection of either
code results in Smartjack loop-up,
if NIU loopback is enabled.

Signal sent in-band.  HDSL
elements in armed state make
transition to loop-up state.
Loop-up state timeout is
programmable from the HTU-C.

Signal sent in-band.  HDSL
element in loop-up state makes
transition to armed state.

Signal sent in-band or over ESF
data link.  HDSL elements in any
state make transition.

HDSL elements in armed state
make transition to disarmed state.

HDSL element in loop-up makes
transition to armed state.

Summary of Contents for 239 HR

Page 1: ...e HRE The unit extends the digital subscriber loop serving range up to 36 kft over 24 AWG twisted wire The HRE is used in conjunction with any span powering T1 HDSL transceiver unit for the central office HTU C and any Low Voltage HDSL transceiver unit for the remote end HTU R Compatible ADTRAN HDSL transceiver units are as follows Figure 1 ADTRAN 239 HRE 1246045L1 239 HRE LP1 LP2 LP1 LP2 LL Y N E...

Page 2: ...ect Table 4 LED Indicators 2 INSTALLATION Remove the ADTRAN 239 HRE from the carton and visually ensure that damage has not occurred during shipping or handling If damage has occurred file a claim with the carrier then contact ADTRAN See Warranty and Customer Service subsection 7 of this practice The ADTRAN 239 HRE is shipped in a separate carton and must be installed in an environmental apparatus...

Page 3: ...vice Area CSA guidelines CSA deployment guidelines are given below 1 All loops are non loaded only 2 For loops with 26 AWG cable the maximum loop length including bridged tap lengths is 9 kft 3 For loops with 24 AWG cable the maximum loop length including bridged tap lengths is 12 kft 4 Any single bridged tap is limited to 2 kft 5 Total bridged tap length is limited to 2 5 kft 6 The total length o...

Page 4: ... ABACON 25 slot 819 25 Polymer 239 819A 12 16 SPC 7130 0656P TA DDMOKJOARA Stainless Air core 239 439 5 6 slot 7130 0656P TB2 DDMOLJOARA 6 Steel Gel filled no 819A Vertical stub down only 6 SPC 7130 V856P TQA DDMOKKOARA Stainless Air core 239 439 7 8 slot 7130 V856P TQB2 DDMOLKOARA 8 Steel Gel filled no 819A Vertical stub down only 8 Keptel 8 8 slot 820 8 Polymer 239 Vertical stub down only 8 AT T...

Page 5: ...us and errors on CUST loop 1 It will flash once when an errored second is detected on CUST loop 1 Off No synchronization with the HTU R Green Synchronized with good signal quality on CUST loop 1 2 dB margin Yellow Synchronized with marginal signal quality on CUST loop 1 1 to 2 dB margin Red Synchronized with poor signal quality on CUST loop 1 0 dB margin CUST LP2 This LED indicates HDSL signal qua...

Page 6: ...HRE customer remote loopback is active Figure 2 CSA Deployment Guidelines 0 12 11 10 9 8 7 6 5 4 3 2 1 0 1 2 3 4 WORKING LENGTH OF 26 GAUGE CABLE KFT WORKING LENGTH OF 24 GAUGE OR COARSER CABLE KFT 5 6 7 8 9 2 5 2 0 1 5 1 0 0 5 0 0 TOTAL BRIDGED TAP LENGTH KFT VALID CSA CABLE LENGTHS INVALID CSA CABLE LENGTHS Performance monitoring diagnostics and loopbacks are also available from the craft interf...

Page 7: ... Weight 1 lb Environment Temperature Operating Standard 40 C to 70 C Storage 40 C to 85 C Relative Humidity Up to 95 non condensing 7 WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within 10 years from the date of shipment if it does not meet its published specifications or fails while in service see ADTRAN Carrier Networks Equipment Warranty Repair and Return Policy and ...

Page 8: ...1246003L4 L8 DDM HTU C 1246004L4 L8 3192 HTU C The HREs and HTU Rs loopback capabilities are controlled from the central office unit HTU C NOTE IftheHTU ConacircuitcontainsStandard loopbacks then refer to subsection 1 of this Appendix to determine its capabilities If the HTU C on a circuit contains Enhanced loopbacks then refer to subsection 2 of this Appendix to determine its loopback capabilitie...

Page 9: ...State transitions result from in band ESF data link sequences and timeout operations The sequences and timeouts are as follows Figure A 2 HDSL Element State Diagram ACTIVATION LOOP UP TIMEOUT ARMING TIMEOUT DEACTIVATION DISARM LOOP UP TIMEOUT DISABLE The Loop up Timeout Disable function is currently not supported LOOP UP TIMEOUT STATE ARMED STATE LOOP UP NO TIMEOUT STATE DISARMED STATE Arming in b...

Page 10: ...HDSL elements make a transition from the disarmed state into the armed state All other control code sequences are ignored in the disarmed state The ESF data link sequence used to simultaneously arm the loopback capability of all HDSL elements is the standard 16 bit ESF data link sequence used for NIU Smartjack loop up Table A 1 HDSL Standard Loopback Control Codes Name Arming In band Arming ESF Ac...

Page 11: ...m Sequence 11100 The disarming process ensures race free operation of HDSL element disarming and Smartjack loop down Duration of the disarm sequence may Table A 2 HDSL Loopback Control Codes Notes The Source column indicates which side of the interface the control codes are sent from For example an N indicates a network sourced code while a C indicates a customer sourced code All codes are inband ...

Page 12: ... up to three HDSL elements The deactivation sequence does not disarm the HDSL elements They can still respond to activation sequence control codes All HDSL elements automatically move from the loop up state into the armed state when the selected loop up timeout value is reached Loop up Timeout programmable from HTU C at None 20 60 or 120 minutes Transition from Loop up to Disarmed State All HDSL e...

Page 13: ... 5 1 3 The HTU C and any HRE units which are in the HDSL circuit are treated as Identical Tandem Dataports and the HTU R is treated as a Different Tandem Dataport Loopback Control Codes A summary of control sequences is given in Table A 3 NOTE In all control code sequences presented the in band codes are shown with the left most bit transmitted first and the ESF data link codes with the right most...

Page 14: ... Loop up C742 1100 0111 0100 0010 1 ESF facility Datalink ESF only when set from the network an HTU R network loopback is activated and a 20 bit error confirmation is sent When set from the customer an HTU R customer loopback is activated with a 20 bit error confirmation Loopdown 9393 1001 0011 1001 0011 2 All units currently in loopback will loop down but remain in the armed state Query Loopback ...

Reviews: