Chapter 8. Telnet/Terminal Menus
8-6
TSU 600 User Manual
61202076L1-1
Figure 8-3.
Unit Access Table
Add New Unit
This adds a new device to the table. You must enter a device Unit ID,
passcode, unit type, and polled flag. The unit type can be Standard
(which supports any TSU/TDU Multiplexer and the ISU 512) or TSU
Standalone (a single port TSU with no option card slot). You can select a
passcode of
0
to
9999
for each device or
DEFAULT
, in which the de-
fault passcode will be used. See Figure 8-3.
Traps are normally sent from the unit in alarm to the TSU 600. For units
in the Unit Access Table that are not chained directly to the TSU 600 but
are managed over Inband or the FDL, traps are not automatically for-
warded. Polling must be enabled on the TSU 600 for these units in order
to receive Traps on the NMS. The TSU 600 can be configured to poll se-
lected units for traps by enabling the polled option when adding or
modifying a unit entry.
Modify Unit
Allows Unit ID, passcode, device type, and polled flag to be changed for
an existing entry in the table.
Delete Unit
Deletes an entry in the table.
__________________Unit Access Table_________________
Unit ID
Passcode
Type
Polled
PollStatus
20
DEFAULT
Standard
No
3
0033
Standard
Yes
UP
6
0095
TSU Stand Alone
No
8
0022
Standard
Yes
UP
1) Add New Unit
2) Modify Unit
3) Delete Unit
4) Default Unit Passcode
0022
5) OK
Summary of Contents for 1202076L1
Page 18: ...List of Figures vi TSU 600 User Manual 61202076L1 1...
Page 20: ...List of Tables viii TSU 600 User Manual 61202076L1 1...
Page 54: ...Chapter 3 Operation 3 14 TSU 600 User Manual 61202076L1 1...
Page 76: ...Chapter 5 Configuration Menu 5 16 TSU 600 User Manual 61202076L1 1...
Page 98: ...Chapter 8 Telnet Terminal Menus 8 10 TSU 600 User Manual 61202076L1 1...
Page 106: ...Appendix B Understanding TR 08 B 4 TSU 600 User Manual 61202076L1 1...
Page 116: ...Appendix E Specifications E 4 TSU 600 User Manual 61202076L1 1...