Chapter 3. Operation
61200310L1-1
Octal and Quad FXO Modules User Manual
3-7
T
EST
Displays the test name if the module is executing a test. Press
Enter
in this
field to activate the menu.
T
EST
2W
Activates 2W (FXO) tests on a per port basis. Test options include
O
FF
(no
tests are active),
L
OOP
O
PEN
,
L
OOP
C
LOSED
,
and
R
ING
G
ROUND
.
page 3-7 displays information about the tests based on Tip and Ring output.
T
X
ABCD
Forces the Tx RBS to a specified value:
O
FF
,
0000
,
0101
,
1010
, or
1111
.
1
K
H
Z
T
ONE
Sends a 1kHz tone into the following locations, based on test selection:
N
EAR
sends the tone out the 2W FXO port, while
F
AR
sends the tone into the digital
PCM stream of the ATLAS 550 controller. These tests are useful for verifying
a voice path.
L
OOPBACK
Activates Loopback tests per port as follows:
The 2W tests disrupt calls in progress.
Table 3-1. Test 2W Information
Test
Tip Output
Ring Output
Loop Open
High impedance
High impedance
Loop Closed
Off-hook impedance
Off-hook impedance
Ring Ground
High impedance
R to ground
Calls may be affected when activating this test.
Off
Normal operation.
Analog
Loops the 2W test on itself.
Digital
Loops digital data entering the FXO on itself.