![background image](http://html.mh-extra.com/html/adtec/en-210/en-210_user-manual_2854096047.webp)
In
the
example
above,
a
raw
PID
was
sent
into
the
system
with
no
program
association.
The
EN
modified
the
main
program
PMT,
Program
1,
to
add
an
additional
DVB
Subtitle
PID
entry.
As
EN
encoders
do
not
perform
PID
conflict
resolution
at
this
time,
the
PID’s
inserted
into
the
system
should
not
conflict
with
other
PID’s
utilized
by
the
EN-31.
To
configure
ASI
Passthrough
of
DVB
subtitles,
visit
the
Manual
PIDs
tab.
This
tab
contains
PMT
template
entries
that
will
be
used
to
insert
into
the
PMT.
The
user
will
need
to
know:
● The
PID
number
of
which
they
would
like
to
pass.
This
can
be
entered
into
the
Hexadecimal
or
Decimal
fields.
● The
Stream
Type
identifier
of
the
PID
that
will
be
written
into
the
PMT.
This
can
be
entered
in
decimal
only.
● The
Descriptor
of
the
PID
that
will
be
written
into
the
PMT.
This
field
is
entered
as
hexadecimal
pairs
where
each
pair
represents
a
byte
field.
Up
to
32
pairs
(64
characters)
can
be