CHIME MODE
Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME
mode. When activated, three tones sound at the Keypad whenever a protected perimeter door or window is
opened, and the “Not Ready” message is displayed. Pressing the
READY
[*] key displays the open protection
points.
Note that Chime mode can be activated only when the system is disarmed.
1.
To turn Chime Mode on,
enter the security code and press the
CHIME
key [9].
2.
To turn Chime Mode off,
enter the security code and press the
CHIME
key again.
KEYPAD TONES
When the Keypad is generating a periodic beep (once per minute), pressing the [*] key provides more
information.
When the system is armed and there is a trouble condition, the Keypad displays “Device Trouble”. Pressing
the [*] key provides more information.
QUICK EXIT
To start Quick Exit when enabled.
Stay Mode – Enter User code + STAY key.
Instant Mode – Enter User code + INSTANT key
Night-Stay Mode – With the system armed in Night-Stay Mode and the exit delay expired,
enter User code + STAY key + STAY key.
HOST CHECK-IN
If Host Check-In interval is set to 200 seconds, “Download Com/Upload Completed” message is displayed at
the Keypad every 200 seconds.
TEST MODE
Use Test mode to check each protection point for proper operation.
Testing should be conducted weekly to ensure proper operation.
1. Disarm the system and close all protected windows, doors, etc.
2. Enter the Master code + [5] (TEST), then press 1.
3. Listen. The external sounder should sound for about 1 second then turn off.
4. Fault all zones in turn and listen for three beeps from the keypad. ID of each faulted point should appear
on the keypad display. The display clears when the zone is closed. Note that if wireless motion detectors
are used, there is a 3-minute delay between activations. This conserves battery life.
5. Test all smoke and CO detectors following the manufacturer's instructions and check the display.
6. When all zones have been checked and are intact (closed), there should be no zone identification
numbers displayed on the keypad.
7. Exit test mode: security code + [1] (OFF).
NOTES:
•
The keypad sounds a single beep about every 60 seconds as a reminder that the system is in the Test
mode.
•
Alarm messages are not sent to your Central Station while Test mode is on.
•
If a problem is experienced with any protection point (no confirming sounds, no display), call for service
immediately.
•
If the test mode is inadvertently left active, it automatically turns off after 30 minutes. During the final
five minutes, the keypad will emit a double beep every 30 seconds.