ADT TSSC-BASE User Manual Download Page 3

– 3 – 

KEYS 

Access the Base control keys by lifting up the door

.  

Access the Keypad keys by opening the swing-down 

door

.  

The Base and Keypad keys are continuously backlit for ease of use.  

KEY 

DESCRIPTION 

OFF

 

Disarms the burglary portion of the system, silences alarms and audible trouble 

indicators, and clears visual alarm trouble after the problem has been corrected. 

AWAY

 

Completely arms both perimeter and interior burglary protection by sensing an intruder's 

movements through protected interior areas as well as guarding protected doors, 

windows, etc. Late arrivals can enter through an entry delay zone (entrance door) without 

causing an alarm if the system is disarmed before the entry delay time expires. 

STAY

 

Arms the perimeter burglary protection, guarding protected doors, windows and other 

perimeter protection points, and sounds an alarm if one is opened. STAY automatically 

bypasses certain areas which permits movement within your house without causing an 

alarm. Late arrivals can enter through an entry delay zone (entrance door) without 

causing an alarm if the system is disarmed before the entry delay time expires. 

NIGHT 

STAY 

Arms similar to STAY mode, but also arms additional pre-selected sensors for increased 

protection while staying inside. Late arrivals can enter through an entry delay zone 

(entrance door) without causing an alarm if the system is disarmed before the entry delay 

time expires, and they do not violate any of the pre-selected sensor areas. An alarm 

occurs immediately if anyone enters those areas while armed.  

MAX

 

Arms in manner similar to AWAY mode, but eliminates the entry delay period, thus 

providing maximum protection. An alarm occurs immediately upon opening any protection 

point, including entry delay zones (entrance doors). (“Arm Instant,” if programmed.) 

TEST

 

(Keypad only) - Tests the system and alarm sounder if disarmed. 

BYPASS

 

(Keypad only) - Removes individual protection zones from being monitored by the system. 

Displays previously bypassed protection zones. 

INSTANT

 

Arms in manner similar to STAY mode, but eliminates the entry delay period, offering 

greater security while inside and not expecting any late arrivals.  An alarm will occur 

immediately upon opening any perimeter protection point, including entry delay zones. 

(“Arm Instant,” if programmed.) 

CODE

 

(Keypad only) - Allows assigning user codes that can be given to other users of the system. 

CHIME

 

(Keypad only) - Turns on and off the CHIME mode. When on, any entry through a 

protected delay or perimeter zone while the system is disarmed will cause a tone to sound 

at the Keypad(s). 

IMPORTANT CHIME WARNING NOTE:

 The Chime feature is intended for 

convenience and is not intended for life safety purposes or pool alarm and does not meet 

the requirements of UL 2017. 

READY

 

(Keypad only) – Pressing the READY key at the Keypad prior to arming displays all open 

protection zones within the Keypad's home partition. This key is also used to display all 

zone descriptors that have been programmed, by holding the key down at least 5 seconds. 

[#]

 

(Keypad only) - Permits ARMING of the system without using a security code ("Quick 

Arm", if programmed). 

Keys 0-9

 

Used to enter your individual security access code(s). 

Special 

function 

keys

 

Panic alarm activation (Keypad only). The panic alarms are activated by pressing a 

Special Function Key (see below). Panic key functionality and the type of panic alarms 

produced is determined by the control panel’s capability and programming. 

(Check with 

your installer for the availability and assignment of these panic keys.)

 

 

SPECIAL FUNCTION KEYS (KEYPAD ONLY) 

The A, B, and C keys located to the left of the 

numeric keys can be programmed as Panic Alarm 

Activation keys. 

(Check with your installer for the 

availability and assignment of these panic keys.)

 

Key

 

Function

 

 

 

 

 

Summary of Contents for TSSC-BASE

Page 1: ...e 1 Low Battery Missing Battery Charging Battery Normal In Programming Red STATUS Not Ready to Arm Armed System Trouble Ready to Arm Device Trouble Can Arm Device Trouble Cannot Arm Alarm Alarm Memory...

Page 2: ...d Amber Green Flashing Green Flashing Amber Flashing Red Alternating Flashing POWER Low Battery Missing Battery when no AC Keypad s battery Charging AC On Battery Normal no AC Low Battery no AC Keypad...

Page 3: ...ogrammed TEST Keypad only Tests the system and alarm sounder if disarmed BYPASS Keypad only Removes individual protection zones from being monitored by the system Displays previously bypassed protecti...

Page 4: ...they do not need to know e g bypassing protection zones Enter Master code CODE key 8 2 two digit user no 4 digit new user s code User numbers 02 through 96 are available with various authority levels...

Page 5: ...every 200 seconds TEST MODE Use Test mode to check each protection point for proper operation Testing should be conducted weekly to ensure proper operation 1 Disarm the system and close all protected...

Page 6: ...acing the battery and reattaching the Keypad to the mounting plate enter the 4 digit security code OFF sequence twice to clear any trouble condition REPLACING THE BATTERY IN A DESK MOUNTED KEYPAD 1 Pl...

Page 7: ...ubject to compromise by sophisticated intruders Even if the system responds to the emergency as intended however occupants may have insufficient time to protect themselves from the emergency situation...

Page 8: ...o a period of 90 days from the date of completion of installation The exclusive remedy of the customer hereunder shall be repair or replacement as stated above Under no circumstances shall ADT be liab...