BASE FEATURES 
Display 

The TSSC-BASE is a wireless Control Unit that allows you to perform system arming and disarming 

functions, as well as to monitor the status of your security system. 

 

 

TSSC-BASE w/Protective Door Removed 

 

Base unit LEDs 

LED 

Off 

Red 

Amber 

Green 

Flashing 

Green 

Flashing 

Amber 

Flashing 

Red 

Alternating 

Flashing 

POWER 

No AC 

 

 

AC 

 

 

 

 

BATTERY 

(see note 1) 

 

Low 

Battery/ 
Missing 

Battery 

Charging 

Battery - 

Normal 

 

 

 

In 

Programming 

- Red 

STATUS 

Not Ready  

to Arm 

Armed 

System 

Trouble 

Ready to 

Arm 

Device 

Trouble 

 

Can Arm 

Device 

Trouble 

 

Cannot 

Arm 

Alarm/Alarm 

Memory 

In 

Programming 

- Off 

NETWORK 

(see note 2)

 

Not 

Configured 

No 

Ethernet 

Link 

Link but 

Not 

Connected 

to Central 

Station 

Ethernet 

Link 

 

 

 

In 

Programming 

- Green 

CELLULAR 

Not 

Configured 

No 

Connection 
or Low 

Signal 

 

Good 

Signal 

 

Cell but No 

Data 

SIM Error 

In 

Programming 

- Off 

NOTE 1:

 During Sleep Mode only the BATTERY LED is active. 

NOTE 2:

 This LED may remain in the Amber state for up to 24 Hours until a report is sent 

and acknowledged by the central station. 

 

Summary of Contents for TSSC-BASE

Page 1: ...e 1 Low Battery Missing Battery Charging Battery Normal In Programming Red STATUS Not Ready to Arm Armed System Trouble Ready to Arm Device Trouble Can Arm Device Trouble Cannot Arm Alarm Alarm Memory...

Page 2: ...d Amber Green Flashing Green Flashing Amber Flashing Red Alternating Flashing POWER Low Battery Missing Battery when no AC Keypad s battery Charging AC On Battery Normal no AC Low Battery no AC Keypad...

Page 3: ...ogrammed TEST Keypad only Tests the system and alarm sounder if disarmed BYPASS Keypad only Removes individual protection zones from being monitored by the system Displays previously bypassed protecti...

Page 4: ...they do not need to know e g bypassing protection zones Enter Master code CODE key 8 2 two digit user no 4 digit new user s code User numbers 02 through 96 are available with various authority levels...

Page 5: ...every 200 seconds TEST MODE Use Test mode to check each protection point for proper operation Testing should be conducted weekly to ensure proper operation 1 Disarm the system and close all protected...

Page 6: ...acing the battery and reattaching the Keypad to the mounting plate enter the 4 digit security code OFF sequence twice to clear any trouble condition REPLACING THE BATTERY IN A DESK MOUNTED KEYPAD 1 Pl...

Page 7: ...ubject to compromise by sophisticated intruders Even if the system responds to the emergency as intended however occupants may have insufficient time to protect themselves from the emergency situation...

Page 8: ...o a period of 90 days from the date of completion of installation The exclusive remedy of the customer hereunder shall be repair or replacement as stated above Under no circumstances shall ADT be liab...

Reviews: