40
3 — Intruder
An Intruder zone is used on devices that require an instant alarm if activated when the
system is Set. During the Set state, zone activations cause internal sounders and external
sounders to activate.
4 — Walk Through
A walk Through zone is used with the Final Exit zone. The unsetting procedure is initiated,
all Walk Through zones are omitted during the Entry Time when the system is set and a
Final Exit zone is activated. This gives users access to a keypad or keyswitch.
If a Walk Through zone is activated first when the system is Full Set it causes a full
alarm.
2 — Keyswitch
A Keyswitch zone has a latching operation.
The Keyswitch should be wired across the zone terminals to Full Set the system. Opening
the Keyswitch zone will start the Full setting procedure. Closing the Keyswitch zone
(closed circuit) instantly unsets the system.
The Keyswitch can also unset the system from Part or Night Set when programmed in
group 2 and 3.
It is strongly recommended that the Keyswitch should be fitted in a Tamper protected
case with the Tamper switch connected in series with the other Tamper circuits at the
control panel.
5 — 24 Hour Tamper
A 24 Hour Tamper zone is used for system tampers and for zones covering sensitive
areas such as stock rooms, fire doors, external bell box, etc.
If a 24 Hour Tamper zone is activated when the system is Unset, the keypads sound and
the corresponding zone is indicated on the keypad. External sounders do not operate.
It is strongly recommended that a zone programmed as 24 Hour Tamper is programmed
in one of the following ways:
• Programmed as 24 Hour Tamper in Groups 1 (Full Set), 2 (Part Set) and 3 (Night
Set).
• Programmed as 24 Hour Tamper in Group 1 (Full Set), and, 0 (Not Used) or 24
Hour Tamper in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
6 — PA Silent
The PA Silent zone type is assigned to a panic button. Activation of a PA Silent zone
does not cause any audible indication and no indication is given on the keypad display