36
Group 9 — Option 1 Communicate Omitted Zones
When choosing Contact I.D. as a communication format, zones can be omitted to prevent
them operating in this mode. This option allows these zones to communicate with the
central station.
This option has two settings:
0.
No (Communicate omitted zones disabled)
1.
Yes (Communicate omitted zones enabled)
This option defaults to 0 (Communicate omitted zones disabled).
Group 9 — Option 2 Invert Set/Unset Signals
This option has two settings:
0.
No (invert Set/Unset disabled).
1.
Yes (invert Set/Unset enabled).
This option defaults to 0 (invert Set/Unset disabled).
If this option is enabled (1), Set signals report a Code 4 signal on Channel 4. If disabled
(2), Unset signals report a Code 2 signal on Channel 4.
Group 9 — Option 3 Double Knock Zone
This option allows one zone to be programmed as a Double Knock zone. The control
panel will only acknowledge the Double Knock zone if it is activated twice within five
minutes, or once for more than ten seconds.
Note: Only one zone can be selected for double knock. If a zone is programmed as
Double Knock, unsetting and setting will not affect the Double Knock status.
0. No Zone.
1-8. Number of zone for double knock.
This option defaults to 0 (No Zone).
Group 9 — Option 4 User Omit Zone
This option has two settings:
0. Zone omit disabled, zones cannot be omitted by the user.
1. Zone isolation enabled, zones can be omitted by the user.
This option defaults to 1 (enabled).
When this option is disabled, three error beeps are heard after a user code is entered and
6 (Omit) is selected.
Note: This option only affects users. The engineer code can omit zones regardless of
this option setting.