Keypad Emulation
Compatibility
The below listing identifies the alarm systems that the 6270ADT can
interface with, the maximum number of 6270ADTs that can be used
with each system, and the minimum alarm panel software revision
level for compatibility.
MAXIMUM NUMBER
MINIMUM SOFTWARE
ALARM SYSTEM OF
6270ADTs REVISION
LEVEL
Safewatch Pro 3000EN
2
All Levels
VISTA-128BPADT 3
2.4
VISTA-250FBPADT 1
1.5
VISTA-15P
2
3 (When available)
VISTA-20P
2
3 (When available)
VISTA-20PS 2
All
Levels
VISTA-128BP 3
2.4
VISTA-128FBP 3
1.6
VISTA-250BP 3
2.4
VISTA-250FBP 1
1.5
On all panels except the residential panels, you may obtain the software
revision level of the alarm panel by entering the program mode and then
entering
#92 on the keypad. The second line of the keypad displays the
software revision level (without the decimal point).
ECP Error
The message “ECP Error” will be displayed at the top of the screen (except for
the Home screen) when the 6270ADT cannot communicate with the alarm
panel. This may be caused by and incorrect ECP address in the 6270ADT or
because AUI type devices have not been enabled in the panel. While this
message is being displayed, you must use the 6270ADT default code of “4140”
any time the 6270ADT requests an authorized code.
Summary of Contents for 6270ADT
Page 2: ......
Page 6: ...vi ...
Page 38: ...6270ADT Installation and Setup Guide 5 8 ...
Page 42: ...6270ADT Installation and Setup Guide 6 4 ...
Page 50: ...6270ADT Installation and Setup Guide 7 8 SCREEN ACTION ...
Page 52: ...6270ADT Installation and Setup Guide 8 2 ...
Page 55: ...NOTES ...
Page 56: ...NOTES ...
Page 57: ...NOTES ...
Page 58: ...NOTES ...
Page 59: ...NOTES ...
Page 60: ...NOTES ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...