is still available; the dynamics modules can be configu-

red to be installed pre the module insert output or post 

the insert input. Once the necessary frame PCB‘s and 

the additional wiring are installed on particular module 

slots, these modules can be upgraded with dynamics mo-

dules at any time. Apart from the TKC-DN, a Compres-

sor-Expander, and combined modules; Compressor-Ex-

pander with PPM meter are available. An upgrade with 

the necessary frame PCB‘s and wiring is possible at the 

location; however it is more expensive.

Meters 

Several different meter versions can be used with all BC4 

Broadcast Consoles. While each standard console has a 

set of ADT high resolution PPM LED meters included, 

which read the program master outputs, the control room 

source select and the group outputs, almost any other 

signal in the console can be assigned to a meter.

Sources

All modules have configurable meter outputs. With in-

put and group modules, there are usually 4 jumpers that 

determine the source signal for an external, additional 

meter. Channel ouput, pre fader and post fader signals 

and the input signal can be selected. With stereo mo-

dules, stereo or mono, external meters are possible. In 

addition to the source selection by jumper blocks per 

channel, a separate matrix can be used to add a mono 

signal for the meter.  

The master modules have meter sends for the auxiliary 

outputs, the program masters, the control room source 

selectors and the PFL master. If no separate PFL meter 

is installed, the control room meter can display the PFL 

master as soon as PFL is active by automatic switching.

Standardized flatcable connects the meter sends of the 

TK-PS

15

178

5

56

5

10

20

3.2

30

1

40

32

10

316

10

560

dB

%

0

100

TK-PM

15

178

5

56

5

10

20

3.2

30

1

40

32

10

316

10

560

dB

%

0

100

module  with  the  meter  frame  boards  in  the  bridge. 

The location of the meters is not fixed and can be se-

lected by the customer. All meters use a single 24 V 

DC supply voltage. A separate supply for the meters 

with appropriate capacity is available with each of the 

power supply units.

Meter Versions

adt-audio hi-res LED PPM

The TK-PS and TK-PM ADT high resolution LED me-

ters are the standard system for the BC4 consoles. The 

meters use 40 LED‘s in a range from +15 dB to -40 dB 

with a resolution of 1 dB in the range from +15 to -10 

dB and 2 dB down to -30 dB. The release time is line-

arized and can be adjusted to the standard value of 

1.5 sec per 20 dB. The attack time is below 1 ms for -1 

db display with an burst input signal of 10 ms @ 5 kHz. 

The meter is available in stereo and mono versions and 

fits into the meter bridge frame boards. It can be used 

for all channels and masters of the BC4 system. A corre-

sponding phase correlation meter is also available.

A different scale plate with a display range from + 10 

dB to - 45 can be installed alternatively. The level ad-

justment range is more than sufficient to use both sca-

les with all possible nominal levels.

adt-audio 10-LED PPM 

An  additional,  low  resolution  version  with  10  LED‘s 

and a total of 30 dB range is available. This is the sa-

me meter that is used with the BC4 input channels in 

a format that fits into the meter bridge. These meters 

are low cost and can be used for auxiliary send or any 

other purpose, alternatively. They are available in mo-

no and stereo configurations.  

Summary of Contents for BC4

Page 1: ...ting conditions Maintainance analoge digitale Tonstudiotechnik Karl Jüngling Inh Dipl Ing Gerd Jüngling Scholtwiese 4 6 D45966 Gladbeck Germany Phone 0 049 2043 51061 Fax 0 049 2043 56844 E Mail info adt audio com Internet www adt audio com www broadcast console com Version 1 22 04 English ...

Page 2: ...BC Broadcast 2 Summary 1 Console Frames 4 2 Installation of the console 9 3 Operating conditions 10 4 Maintainance 11 ...

Page 3: ...d crossover devices that are necessary for fail safe power supply configurations and the implementation of the mains connections Chapter 2 is about the audio installation Besides detailed information about basic principles of audio installation and the methods of grounding this chapter contains all pinning diagrams pictures and graphics about the locations of the connectors and a detailed descript...

Page 4: ...at can be used with the floorstand as well Side view The side view shows are all dimensions of the frame The height above floor is deter mined by the height of the floorstand and can be adapted to special needs Frame Width The width of the frames depends of the number of modules of a particular conso le The width of a single slot is 40mm All input and group modules are arranged in a grid of 4 modu...

Page 5: ...ion in the frame must be deter mined with the order It is not possible to change this positi on later Groups A BC4 broadcast console can be equipped with 0 4 8 12 or 16 groups Since the standard mo dules have a routing section for 8 mono groups that can be im plemented for 8 stereo groups as well 8 group modules are standard With small consoles 4 groups may be appropriate The group modules use spe...

Page 6: ...makes it possible to install input modules when the particular blind panel section is no longer needed 3 2 4 Variantes All frames are basically tabletop versions The available floorstand is fixed to flange plates on the left and right side of the frame These floor stands can used with all console versions The only difference between the tabletop frame and the floorstand version is the wooden side ...

Page 7: ...n as PFL is active by automatic switching Standardized flatcable connects the meter sends of the TK PS 15 178 5 56 5 10 20 3 2 30 1 40 32 10 316 10 560 dB 0 100 TK PM 15 178 5 56 5 10 20 3 2 30 1 40 32 10 316 10 560 dB 0 100 module with the meter frame boards in the bridge The location of the meters is not fixed and can be se lected by the customer All meters use a single 24 V DC supply voltage A ...

Page 8: ...ters are available as well The pictures on this page show some of the available versions Please check the RTW website www rtw de for details about the different versions All RTW devices need special front panels and special wiring These meters do not fit into the standard meter frameboards The series 1000 can be adapted to the frame PCB s while the series 1100 devices require a frame slot where no...

Page 9: ...s You can reach these screws from the bottom of the box Remove the screws to free the main frame Check carefully to verify that the console was not damaged during transit If there is damage inform the forwarder before you continue Do not alter anything and make sure to take some pictures of the damage In most cases transport insurance will cover any damage this however depends on the details of th...

Page 10: ...ge Check if all the modules are properly installed in the frame If you are sure that everything is okay switch the system on and check if all control LED s of the power supply are on It is a good idea to install the speaker system in the next step and make a quick test if all channels work 3 Operating conditions Environments The environmental conditions have a great influence on the long term stab...

Page 11: ...nd any special setting that caused the problem This helps a service technician to locate problems Many problems that come up in a particular setting only may not be easily reconstructed after the end of a session The more precise the notation in the logbook the more likely it is that mistakes that are caused by a bad cable or anything else that is not a problem of a function of the console itself ...

Page 12: ...o avoid trouble Once you have applied conventional contact spray to a module you have to use this repeatedly There is no way to remove the spray out of switches or faders unless these components are replaced Some technicians use Vaseline as a protection against corrosion The biggest problem with Vaseline is that it starts to melt when the temperature is higher than 40 C If Vaseline is used for the...

Reviews: