background image

BC

Broadcast

12

���������

type CRC3-36, brand CRC, Belgium. If you cannot get this oil, you can 

order it from the factory.

This cleaner contains a non-aggressive, non-permanent solvent that 

dissolves hardened fat and grease effectively. The second component is a 

good, non-hardening, penetrating oil that protects the cleaned surface for 

a long time. CRC3-36 comes as aerosols that make it easy to apply the 

agent.

Using CRC3-36 with pushbutton switches is very easy. Remove a module 

and put it on a table so that you can see the topside of the switches. 

Press the knob of the aerosol tin carefully while you put the end of the 

little tube that comes the tin next to the locker block at the top of the 

switch. By pressing the knob carefully, you can produce oil foam. Apply 

approximately 1 cubic cm of this foam to each switch that has to be 

cleaned. Wait some minutes before you operate each switch 5 to 10 time. 

With this procedure, you can keep all the switches in a good shape for an 

unlimited period.  

DO NOT USE ANY KIND OF CONTACT SPRAYS!

DO NOT USE VASELINE OR SIMILAR GREASE!

DO NOT DIP AN ENTIRE MODULE INTO A CLEANING BATH!

Please follow these rules to avoid trouble. Once you have applied 

conventional contact spray to a module, you have to use this repeatedly. 

There is no way to remove the spray out of switches or faders unless these 

components are replaced. Some technicians use Vaseline as a protection 

against corrosion. The biggest problem with Vaseline is that it starts to 

melt when the temperature is higher than 40 °C. If Vaseline is used for 

the cleaning of switches, you have to deal with the problem that after the 

temperature exceeds 40 ° C, the entire contact area of the switch will 

be covered in Vaseline. As soon as the temperature drops down below 

40 degrees, the fat hardens again. This causes considerable contact 

problems. If you put an entire module into a cleaning bath, for instance 

of an ultrasonic cleaner, the only effect is, that you distribute all the dirt 

equally to the entire module. This means that the dirt will be inside pots, 

switches, and everything else. Modules that were treated in this way, will 

never work properly again.

Screws 

After a period of about 4 years, the power supply unit should be 

opened and all screws of the transformer and the prints should be re-

tightened. The thermal situation in a power supply makes it likely that 

screws in terminator blocks will loose their contact pressure for the high 

temperature difference between the on and off state. 

Summary of Contents for BC4

Page 1: ...ting conditions Maintainance analoge digitale Tonstudiotechnik Karl Jüngling Inh Dipl Ing Gerd Jüngling Scholtwiese 4 6 D45966 Gladbeck Germany Phone 0 049 2043 51061 Fax 0 049 2043 56844 E Mail info adt audio com Internet www adt audio com www broadcast console com Version 1 22 04 English ...

Page 2: ...BC Broadcast 2 Summary 1 Console Frames 4 2 Installation of the console 9 3 Operating conditions 10 4 Maintainance 11 ...

Page 3: ...d crossover devices that are necessary for fail safe power supply configurations and the implementation of the mains connections Chapter 2 is about the audio installation Besides detailed information about basic principles of audio installation and the methods of grounding this chapter contains all pinning diagrams pictures and graphics about the locations of the connectors and a detailed descript...

Page 4: ...at can be used with the floorstand as well Side view The side view shows are all dimensions of the frame The height above floor is deter mined by the height of the floorstand and can be adapted to special needs Frame Width The width of the frames depends of the number of modules of a particular conso le The width of a single slot is 40mm All input and group modules are arranged in a grid of 4 modu...

Page 5: ...ion in the frame must be deter mined with the order It is not possible to change this positi on later Groups A BC4 broadcast console can be equipped with 0 4 8 12 or 16 groups Since the standard mo dules have a routing section for 8 mono groups that can be im plemented for 8 stereo groups as well 8 group modules are standard With small consoles 4 groups may be appropriate The group modules use spe...

Page 6: ...makes it possible to install input modules when the particular blind panel section is no longer needed 3 2 4 Variantes All frames are basically tabletop versions The available floorstand is fixed to flange plates on the left and right side of the frame These floor stands can used with all console versions The only difference between the tabletop frame and the floorstand version is the wooden side ...

Page 7: ...n as PFL is active by automatic switching Standardized flatcable connects the meter sends of the TK PS 15 178 5 56 5 10 20 3 2 30 1 40 32 10 316 10 560 dB 0 100 TK PM 15 178 5 56 5 10 20 3 2 30 1 40 32 10 316 10 560 dB 0 100 module with the meter frame boards in the bridge The location of the meters is not fixed and can be se lected by the customer All meters use a single 24 V DC supply voltage A ...

Page 8: ...ters are available as well The pictures on this page show some of the available versions Please check the RTW website www rtw de for details about the different versions All RTW devices need special front panels and special wiring These meters do not fit into the standard meter frameboards The series 1000 can be adapted to the frame PCB s while the series 1100 devices require a frame slot where no...

Page 9: ...s You can reach these screws from the bottom of the box Remove the screws to free the main frame Check carefully to verify that the console was not damaged during transit If there is damage inform the forwarder before you continue Do not alter anything and make sure to take some pictures of the damage In most cases transport insurance will cover any damage this however depends on the details of th...

Page 10: ...ge Check if all the modules are properly installed in the frame If you are sure that everything is okay switch the system on and check if all control LED s of the power supply are on It is a good idea to install the speaker system in the next step and make a quick test if all channels work 3 Operating conditions Environments The environmental conditions have a great influence on the long term stab...

Page 11: ...nd any special setting that caused the problem This helps a service technician to locate problems Many problems that come up in a particular setting only may not be easily reconstructed after the end of a session The more precise the notation in the logbook the more likely it is that mistakes that are caused by a bad cable or anything else that is not a problem of a function of the console itself ...

Page 12: ...o avoid trouble Once you have applied conventional contact spray to a module you have to use this repeatedly There is no way to remove the spray out of switches or faders unless these components are replaced Some technicians use Vaseline as a protection against corrosion The biggest problem with Vaseline is that it starts to melt when the temperature is higher than 40 C If Vaseline is used for the...

Reviews: