Page 1: ...Last changed 2021 07 13 Instruction manual Industrial monitors OPD9000 series Translation of the original instruction manual ...

Page 2: ...in particular about its intended use safety installation utilisation maintenance and disposal Hand over the instructions to the user following installation of the product and pass the manual on to the new user if the product is resold These instructions can be downloaded from www ads tec de in the download area Publisher ads tec Industrial IT GmbH Heinrich Hertz Straße 1 72622 Nürtingen Phone 49 7...

Page 3: ... 9 2 2 Intended use 9 2 3 Improper use 10 2 4 Environmental conditions 11 2 4 1 Vibration shock resistance 12 2 5 Conformity 13 2 6 Warranty repairs 14 2 7 Limitation of liability 14 3 Scope of delivery 15 4 Mechanical installation 16 4 1 Requirements 16 4 2 Installation recess OPD9016 16 4 3 Installation recess OPD9019 17 4 4 Installation recess OPD9024 17 4 5 Device installation Sequence 18 5 El...

Page 4: ... 4 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 10 Dimensional drawings 25 10 1 OPD9016 25 10 2 OPD9019 26 10 3 OPD9024 27 11 Technical data 28 12 Service support 29 12 1 ADS TEC support 29 12 2 Company address 29 ...

Page 5: ...ried out safely All users must read this instruction manual and have access to it at all times The original version of this instruction manual was written in German All non German versions of this instruction manual are translations of the German instruction manual 1 2 Explanation of safety instructions 1 2 1 Structure of safety instructions The signal word classifies the hazard Reference to the t...

Page 6: ...ath or severe injury could result CAUTION Indicates a possible danger If not avoided light or minor injuries could result ATTENTION Indicates a possibly damaging situation If not avoided the system or something in its surroundings could be damaged Recommendation for use Indicates terms and or conditions that strictly need to be observed to ensure optimised and or zero defect operation Tips and sug...

Page 7: ...teries may not be disposed of with household waste but must rather be disposed of separately Used batteries must be returned to the point of sale or a disposal system Label on electrical and electronic devices Electrical and electronic devices must not be disposed of with household waste but must rather be taken to a collection point for waste electrical equipment Symbol for the protective earth c...

Page 8: ... used third party trademarks are hereby acknowledged In the case of trademark infringement ADS TEC reserves the right to exercise all rights 1 7 Copyright This instruction manual is protected by copyright For the authorised user simple usage rights are granted within the scope of the intent of the contract Any modified use or exploitation of the provided content particularly duplication modificati...

Page 9: ... IP protection class permits only indoor installation The operator alone shall be responsible for ensuring that all operator obligations are observed and for complying with any technical or statutory amendments that may arise Installation commissioning and operation may only be performed by qualified and trained personnel Intervention by the user is required only for performing the actions describ...

Page 10: ...the case of transport damage or nonconformity with the specifications and must be taken out of operation in the case of changing conditions In the case of improper use ADS TEC shall not accept responsibility or liability for injury or damage that is directly or indirectly attributable to the handling of the device If the device is opened up by an unauthorised person the user may be subject to haza...

Page 11: ... Damage caused by heat If the device is installed in a panel casing or similar heat accumulation can occur Make sure that heat can be dissipated from the device ATTENTION Damage caused by condensation If the temperature of the device is different to that of the environment in which it is located condensation can form Switch on the device only after it has acclimated to the ambient temperature ATTE...

Page 12: ...y 1 octave min Deflection 3 mm Amplitude 10 m s Test duration 2 h per axis DUT status DUT electrically in operation Test criterion Visual inspection after the test and functionality of the DUT during and after the test Shock resistance near machines or conveyor belts DUT functional device Test standard EN 60068 2 27 Shock form semi sinusoidal Test axes X Y Z Amplitude 250 m s Duration 11 ms Test d...

Page 13: ...e industrial sector Class A may cause interference when used in residential environments The EU conformity declaration can be requested at http www ads tec de support support anfrage html and is available for download at http www ads tec de support download eg konformitaetserklaerung html Recommendation for use For full compliance with the EMC legislation all components and cables used for device ...

Page 14: ... injury property damage or damage caused to the device as well as consequential damage that is was the result of non compliance with this instruction manual improper use of the device repairs and other actions on the device by unqualified electricians and electricians not certified by ADS TEC or that is was the result of using unapproved replacement parts Failure to observe the maintenance interva...

Page 15: ...ry Check that the contents of the package are intact If there are signs of damage please contact the manufacturer immediately The device must not be put into operation Check that the contents of the package are complete and match your order 1 x device 1 x 3 pin connector for power supply Accessories according to order delivery note ...

Page 16: ...ments The device is intended to be installed in a wall recess The installation site must be accessible from the rear The wall can be between 1 5 and 6 mm thick The operating company must ensure that the wall can support the weight of the device 4 2 Installation recess OPD9016 The external device dimensions are given in Section 10 Dimensional drawings ...

Page 17: ...OPD9000 series Instruction manual v1 0 17 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 4 3 Installation recess OPD9019 4 4 Installation recess OPD9024 ...

Page 18: ...ill protrude slightly from the housing due to spring pressure 2 Press the loosened clamps in and insert the device into the wall recess from the front 3 Once the device is in place the spring tension should cause the clamps to snap over the inner edge of the wall recess 4 If necessary also loosen the remaining clamps 5 Make sure that all clamps are fully in contact with the rear side of the recess...

Page 19: ...the device Conductor cross sections PE AWG 16 1 5 mm2 optimal AWG 13 2 5 mm2 The cable colour must be green yellow ATTENTION Damage due to electrostatic discharge Damage to the device can be caused by electrostatic discharge Always adhere to the safety measures applicable when handling components at risk of being damaged by electrostatic discharge ATTENTION Damage to the electronics The electronic...

Page 20: ...ion 5 4 3 DisplayPort 1 2 4 HDMI 5 3 x USB 2 0 type A 6 1 x USB 2 0 type B 7 Optional HDBaseT extender RJ45 5 4 Power supply 1 Reference potential GND The figure shows the socket inside the device 2 n c 3 24 VDC 25 Conductor cross sections V 0V AWG 18 0 75 mm2 1 2 3 4 5 6 7 The permissible voltage ranges and the maximum values for the current and power consumption can be found in Section 12 2 Tech...

Page 21: ...be used to connect the monitor and computer is o HDMI up to max 15 m o DisplayPort up to max 10 m o USB 2 0 up to max 15 m with active hubs otherwise 5 m For long distances between the display and the computer you will need the HDBaseT version o HDBaseT up to max 100 m see also Section 7 2 Recommendation for use Note the maximum cable lengths for the respective application type ...

Page 22: ...ning 6 1 Requirements 6 2 Switching the device on The monitors start immediately after the power supply is switched on ATTENTION Hazard due to condensation Damage to electronic components caused by condensation resulting from temperature fluctuations Switch on the device only after it has acclimated to the ambient temperature ...

Page 23: ... that can be bridged depend on the network infrastructure used with a CAT6a patch cable without sockets etc maximum 70 m with a Cat 7 or 7a LAN installation cable sockets two 1 m patch cables maximum 100 m Status indicators of the receiver module The two LEDs in the connector indicate various system states LED signal Action HDCP Flashing red No active encryption HDBT On Connection present Off No c...

Page 24: ...tely into the housing against the spring pressure 3 Tighten the clamping screws counter clockwise as far as they will go so that the clamps are fixed in the housing and do not prevent the device from being removed from the wall recess 4 Remove device from the wall recess ATTENTION Depending on the installation situation have a person hold the front of the device if needed to prevent it from fallin...

Page 25: ... manual v1 0 25 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 10 Dimensional drawings 10 1 OPD9016 The dimensions of the wall recesses for installation can be found in Section 4 Mechanical installation ...

Page 26: ...OPD9000 series Instruction manual v1 0 26 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 10 2 OPD9019 ...

Page 27: ...OPD9000 series Instruction manual v1 0 27 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 10 3 OPD9024 ...

Page 28: ... 1 x DisplayPort 1 2 3 x USB 2 0 1 x USB slave Optional interfaces 1 x HDBaseT interface receiver Power supply 24 VDC 25 max 45 W max 2 5 A 24 VDC 25 max 55 W max 3 A 24 VDC 25 max 45 W max 1 8 A Permiss ambient temperature In operation 0 to 45 C For storage 25 to 70 C Protection class IP65 front IP20 rear side humidity 5 to 95 non condensing Vibration shock resistance See Section 2 4 1 Environmen...

Page 29: ... tec will not be able to answer such questions ADS TEC does not provide support services for any device that was not purchased directly from ADS TEC In this case maintenance and support is provided by the partner company 12 1 ADS TEC support The ADS TEC support team is available for inquiries from direct customers between 8 30am and 5 00pm Monday to Friday The support team can be reached via phone...