background image

U.S. Patent No. 8,856,780

REMOTE STARTER ERROR CODES

 - 1 OF 1

REMOTE STARTER ERROR CODES:

NOTES

[X] NUMBER OF  PARKING LIGHT  FLASHES

DIA

GNOSTIC

I WARNING: The following applies only when the parking 

lights are connected and supported by the system.

01

Engine running. 

02

Key in ignition at ON position.

II After a remote starter failure, the parking lights will fl ash 

three [3x] times, then will fl ash [X] number times to 

indicate an error code. See table.

03

Door is open.

04

Trunk is open.

05

Foot brake is ON. 

06

Hood is open.

07

The reservation is OFF. (Manual transmission only)

08

Tach failure.

09

The vehicle is moving (VSS).

10

System is in Valet Mode. 

11

CAN communication failure

12

RS not synchronized. Start vehicle with OEM key for 15 sec before trying a new RS sequence.

13

Bypass problem.

REMOTE STARTER SHUTDOWN ERROR CODES:

NOTES

[Y] NUMBER OF  PARKING LIGHT  FLASHES

DIA

GNOSTIC

I WARNING: The following applies only when the parking 

lights are connected and supported by the system.

01

Engine tach signal is lost.

02

Emergency brake is lost.

II

If the engine shuts down after a remote starter sequence: 

Press and hold the Trunk button and the Start button at the 

same time for 2.5 seconds when using a 1-WAY remote. 

OR 

Press once [1x] on button “4” when using a 2-WAY remote. 

The parking lights will fl ash four [4x] times, then will fl ash 

[Y] number times to indicate an error code. See table.

03

Foot brake is ON. 

04

Hood is open.

05

Engine RPM limiter is ON.

06

Glow plug timeout error.

07

Vehicle is moving (VSS).

08

N/A

09

N/A

10

Door is open.

11

CAN communication failure during RS sequence.

12

RS not synchronized. Start vehicle with OEM key for 15 sec before trying a new RS sequence.

13

Takeover is not allowed.

14

Shutdown error, board overheat protection.

www.idatalink.com

Automotive Data Solutions Inc. © 2016

HC2351AC

PAGE 11 OF 12

• 20161024

Summary of Contents for idatastart HC2351AC

Page 1: ...mproper installation of this product be that either damage to the vehicle itself or to the installed device This device must be installed by a certified technician Please review the Installation Guide carefully before beginning any work U S Patent No 8 856 780 PRODUCT GUIDE HC2351AC www idatalink com Automotive Data Solutions Inc 2016 ...

Page 2: ...t firmware for your vehicle and that you carefully review the install guide 1 866 427 2999 support idatalink com idatalink com support www 12voltdata com forum www facebook com groups idatatech TABLE OF CONTENTS Box Contents 3 Tach Programming Procedure 4 Remote Programming Procedure 5 Valet Mode Programming Procedure 6 Compatible Accessories 7 Online Module Settings 9 Module Diagnostics 10 Remote...

Page 3: ...E WHITE BLACK DOT GWR OUTPUT 07 EMPTY 07 EMPTY 08 WHITE PURPLE BLACK DOT POC 1 2ND UNLOCK OTHER DOORS OUTPUT 08 WHITE PURPLE BLACK DOT POC 1 2ND UNLOCK OTHER DOORS OUTPUT 09 PURPLE BLACK BLACK DOT POC 2 RAP SHUTDOWN OUTPUT 09 PURPLE BLACK BLACK DOT POC 2 RAP SHUTDOWN OUTPUT 10 WHITE BLACK BLACK DOT POC 3 HORN OUTPUT 10 WHITE BLACK BLACK DOT POC 3 HORN OUTPUT 11 BROWN BLACK BLACK DOT POC 4 STARTER ...

Page 4: ...pedal Press and release the module s programming button OR if the remotes are already programmed to the vehicle press and hold the start button of the remote for 2 5 seconds Wait LED 2 will flash GREEN See the Module Diagnostics page Release the brake pedal Module Programming Procedure completed www idatalink com Automotive Data Solutions Inc 2016 HC2351AC PAGE 4 OF 12 20161024 ...

Page 5: ...the antenna button then press and hold the antenna button The antenna s leds will turn solid BLUE Parking Light will flash once 1x Press once 1x on the LOCK button of each remote The antenna s leds will flash BLUE once 1x for each successful pairing Release the antenna button The antenna s leds will turn OFF Set ignition to OFF position Remote Programming Procedure completed To program an additional...

Page 6: ...ctional See RF kit user manual for alternate valet mode programming Time restriction Complete next step within 7 seconds Cycle ignition ON twice 2x OFF ON rapidly Press and release the BRAKE pedal three times 3x Parking Light will flash once 1x then will flash twice 2x Set ignition to OFF position Valet Mode Programming Procedure completed To exit valet mode repeat steps 1 to 5 www idatalink com Aut...

Page 7: ...rtStart use the module s RED Telematic port NC TELEMATIC KIT accessory sold separately 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 WEBLINK MOBILE accessory sold separately MOBILE DEVICE PORT OBDII CONNECTOR 4 PIN BLACK CABLE MODULE WEBLINK PORT OBDII CONNECTOR WEBLINK CABLE required accessory sold separately WEBLINK CABLE COMPUTER USB PORT 4 PIN BLACK CABLE MODULE WEBLINK PORT ...

Page 8: ...U S Patent No 8 856 780 www idatalink com Automotive Data Solutions Inc 2016 HC2351AC PAGE 8 OF 12 20161024 COMPATIBLE ACCESSORIES 2 OF 2 4 PIN BLACK CABLE MODULE RF PORT RF KIT included ANTENNA ...

Page 9: ... Set transmitter AUX buttons controls MENU 5 Programmable outputs POC Set actions for programmable outputs MENU 6 Pulse Timer Output Configuration PTO Set duration for pulse timer outputs if used MENU 7 Input Configurations Set inputs for Auto by firmware Data Analog MENU 8 Output Configurations Set outputs for Auto by firmware Data Analog Programming options are avaible through Weblink and Weblin...

Page 10: ...de 5 RED flashes Tach set for VTS No tach programming required 6 RED flashes Tach set for assumed start No tach programming required III DURING REMOTE START Flashing RED Module incorrectly programmed Solid RED Module incorrectly programmed Flashing GREEN Module correctly programmed and operational Solid GREEN then OFF Reset in progress OFF Invalid ground when running status from remote starter IV WI...

Page 11: ...OR CODES NOTES Y NUMBER OF PARKING LIGHT FLASHES DIAGNOSTIC I WARNING The following applies only when the parking lights are connected and supported by the system 01 Engine tach signal is lost 02 Emergency brake is lost II If the engine shuts down after a remote starter sequence Press and hold the Trunk button and the Start button at the same time for 2 5 seconds when using a 1 WAY remote OR Press...

Page 12: ...he M1 BLACK 8 pin connector and the M4 BLACK 20 pin connector PRESS AND HOLD the module s programming button while connecting the M1 BLACK 8 pin connector and the M4 BLACK 20 pin connector Wait LED 1 will flash RED RELEASE programming button LED 1 will turn RED for 2 seconds Module RESET completed Reconnect all connectors Repeat programming procedure Failure to follow procedure may result with a DT...

Reviews: