U.S. Patent No. 8,856,780
MODULE DIAGNOSTICS
- 1 OF 1
TEST MODULE
LED 1 ST
ATUS
DIA
GNOSTIC
I
DURING MODULE PROGRAMMING
Flashing RED
Missing/wrong information from fi rmware or vehicle.
Solid RED
Module waiting for more vehicle information.
Flashing GREEN
Additional steps required to complete module programming.
Solid GREEN then OFF
Module correctly programmed.
OFF
No activity or module already programmed.
II
DURING TACH PROGRAMMING
1 GREEN fl ash
Tach signal programmed in Analog
2 GREEN fl ashes
Tach signal programmed in Data
3 RED fl ashes
No tach signal detected
4 RED fl ashes
System is in valet mode
5 RED fl ashes
Tach set for ‘VTS’. No tach programming required
6 RED fl ashes
Tach set for ‘assumed start’. No tach programming required
III
DURING REMOTE START
Flashing RED
Module incorrectly programmed.
Solid RED
Module incorrectly programmed.
Flashing GREEN
Module correctly programmed and operational.
Solid GREEN then OFF
Reset in progress.
OFF
Invalid ground when running status from remote starter.
IV
WITH IGNITION OFF
Flashing RED
Module incorrectly programmed or connected.
Solid RED
Module not programmed. Waiting for more vehicle information.
Flashing GREEN
False ground when running status from remote starter.
Solid GREEN then OFF
Reset in progress.
OFF
Module at rest and ready for a remote start sequence.
www.idatalink.com
Automotive Data Solutions Inc. © 2016
HC2351AC
PAGE 10 OF 12
• 20161024