VMT7000 series
16
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
4.3 Autostart function
The autostart function allows the automatic start-up of the device upon application of the supply voltage
of 24V / 48V DC.
Recommendation for use:
The Autostart switch in the service slot must be set to ON in order to use this
function.
Pos : 28 /D atent ec hni k/Schnitts tell en/Lauts prec her/Lauts prec her f ür VMT 60xx @ 1\ mod_1228482989111_6. doc @ 4247 @
4.4
USB connections
The USB interfaces are used for connecting peripherals with USB connection. These interfaces comply
with the USB 2.0 standard requirements.
PIN number
Signal name
1
VDC
2
D -
3
D +
4
GND
4.4.1 Service slot
There are 3 USB connections in the service slot of the device.
Recommendation for use:
The total current at each USB interface is limited to 1 A.The device supports
a maximum of 8 external USB mass storage devices. If a USB Flash SSD is
installed, a maximum of 7 USB mass storage devices can be connected.
Recommendation for use:
The USB interfaces can be individually locked by using the "Lock USB"
software tool.
Pos : 30 /D atent ec hni k/Schnitts tell en/PS2/Kombi Buc hs e f ür VMT 60xx @ 2\ mod_1268840073235_6. doc @ 7482 @
4.4.2 Front panel
There is a USB interface on the front side. It is protected against dust and dirt by a cover.
Recommendation for use:
It should remain closed when not in use in order to ensure the IP protection.
Pos : 31 /D atent ec hni k/Schnitts tell en/Netz werkansc hlus s RJ 45/Netz wer kansc hluss RJ 45 für VMT 60xx @ 2\ mod_1260451135970_6. doc @ 6856 @